6.0 Troubleshooting
TYPES OF PROBLEM TRY THIS...
1
Nothing works. Check if the unit is plugged in.
Check if the unit is receiving power
from the house circuit breaker.
2 Condensation on windows. Adjust the humidity control knob
as per instructions (see Section 4).
Operate the unit at maximum
speed during activities generating
excess humidity (family gatherings,
extra cooking, etc.).
Leave curtains half-open to allow
air circulation on windows.
Store wood in a closed room with a
dehumidifier or have the room well
ventilated with outside air or store
the wood outside.
Do not adjust the thermostat of your
heating system below 18°C (64°F).
3 Air too dry. Do not adjust your humidity control
below -20°C (-4°F).
Operate the unit at low speed.
Temporarily stop air exchange.
Temporarily use a humidifier.
4 Air too cold at the air supply grille. Make sure the stale air exhaust
hood, outside the house, is not
blocked.
Operate the unit at low speed.
Have the system balancing
checked.
Have the unit defrosting system
checked.
Install a duct heater.