How to fix air that is too dry with my Venmar PRO250 Fan?
- JJames YangAug 5, 2025
To address overly dry air: * Use a humidifier temporarily. * Set the unit at low speed using the integrated control.
How to fix air that is too dry with my Venmar PRO250 Fan?
To address overly dry air: * Use a humidifier temporarily. * Set the unit at low speed using the integrated control.
What to do if nothing works on my Venmar PRO250 Fan?
First, verify that the unit is correctly plugged into the power outlet. Then, check if the unit is receiving power from the house circuit breaker or fuse. Ensure that the breaker hasn't tripped or the fuse hasn't blown.
Why is there condensation on windows with my Venmar Fan?
Condensation on windows, indicating overly humid air, can be addressed by several actions: * Adjust the humidity control knob according to the instructions. * Leave curtains partially open to improve air circulation. * Store firewood in a closed room with a dehumidifier, a well-ventilated area, or ideally, outside. * Maintain a house temperature above 18°C (64°F). * Increase the unit's speed during activities that generate significant humidity, such as large gatherings or extensive cooking.
What to do if the LED of my Venmar PRO250 Fan integrated control is blinking amber?
If the LED of the integrated control is blinking amber, it indicates a problem with the motorized damper. The unit is OFF. For a 2½-hour period, the unit will try to reset the damper at every 30 minutes. After 2½ hours, if the problem is not solved, the unit stops trying to reset damper. Check control wiring.
Why is the air too cold at the air supply grille of my Venmar Fan?
If the air is too cold at the air supply grille, take the following steps: * Ensure that the outside ports are not blocked. * Set the unit at low speed using the integrated control. * For PRO250 units with Breeze control, set the unit at minimum speed (MIN.).
What to do if the LED of my Venmar PRO250 Fan integrated control is blinking red?
If the LED of the integrated control is blinking red, it means there is a problem with the exhaust motor. The unit is OFF.
What to do if the LED of my Venmar Fan integrated control is blinking green?
If the LED of the integrated control is blinking green, it indicates a problem with the thermistor. The unit is still working, but will defrost frequently.
Explains how the unit exhausts stale air and brings in fresh air for improved indoor air quality.
Details how the unit transfers heat between stale and fresh air streams to reduce energy costs.
Describes the unit's recirculation function for air purification without exterior exchange.
Outlines house configurations, kits, and ideal unit placement for installation.
Lists necessary tools, materials, and covers the unit hanging procedure.
Covers duct planning, installing flexible ducts, and connecting registers.
Details connecting ducts to ports, exterior ports, and the drainage system.
Explains the operation and LED indicators of the unit's built-in control.
Details how to properly connect external controls to the unit's terminal block.
Guides on installing the main control panel, including wiring connections.
Explains Breeze control operation for PRO250, including air supply and humidity adjustments.
Details usage of 11136 control for PRO225, focusing on humidity level selection.
Describes the purpose and operation of the optional 20-minute lighted push button control.
Outlines routine tasks like cleaning filters, checking ports, and core care.
Details recommended annual service checks, including core, blades, and tray cleaning.