VB0181
USER MANUAL
NEE
2000 HE
3000 HE
READ AND SAVE THESE INSTRUCTIONS
ADDRESS OF YOUR INSTALLER
02053 REV. 06
VENMAR
1.8 HE
2.6 HE
RESIDENTIAL PRODUCTS GROUP, 550 LEMIRE BLVD.,
DRUMMONDVILLE, QC, CANADA J2C 7W9

Other manuals for Venmar 2.6 HE

Questions and Answers

  • J
    Juan FloresAug 8, 2025
    What to do if my Venmar Fan is not working?
    • R
      Robert TaylorAug 8, 2025
      If your Venmar Fan isn't working, first, check if the unit is properly plugged into the power outlet. Second, verify that the unit is receiving power from the house circuit breaker or fuse.
  • J
    James KellyAug 13, 2025
    Why is my Venmar Fan so noisy?
    • J
      Jeremy TaylorAug 13, 2025
      If your Venmar Fan is making excessive noise, you should clean the unit. If the problem persists after cleaning, it is recommended to contact your installer for further assistance.
  • C
    Cheryl LopezAug 19, 2025
    How to reduce condensation on windows caused by my Venmar 2.6 HE?
    • C
      Christopher WrightAug 19, 2025
      To reduce condensation on windows when using your Venmar Fan, try the following: Operate the unit at maximum speed during activities that generate a lot of humidity, like cooking or family gatherings. Leave curtains half-open to improve air circulation. Store firewood in a closed room with a dehumidifier, a well-ventilated room, or outdoors. Ensure the temperature in your house stays above 18°C (64°F).
  • E
    Erin Nelson MDAug 27, 2025
    What to do if air from my Venmar Fan is too cold?
    • J
      Jennifer RogersAug 27, 2025
      If the air from your Venmar Fan is too cold, ensure that the outdoor hoods are not blocked. Operate the unit at low speed. It's also recommended to have the system's balancing and the unit's defrost system checked. Installing a duct heater is another possible solution.
  • F
    Francis MooreSep 1, 2025
    How to fix dry air with Venmar Fan?
    • D
      Derrick CastilloSep 1, 2025
      If the air is too dry when using your Venmar Fan, try operating the unit at low speed. You can also temporarily switch to the intermittent mode or use a humidifier to increase the humidity.

Summary

FUNCTIONS OF YOUR HRV

AIR EXCHANGE

Exhausts stale air and draws in fresh air for improved indoor quality.

HEAT RECOVERY

Recovers heat from stale air to pre-condition incoming fresh air.

RECIRCULATION

Purifies indoor air by circulating it without exchanging with outdoors.

DIAGRAMS OF AIRFLOW

DESCRIPTION OF THE UNIT

MAIN AND AUXILIARY CONTROLS

MAINTENANCE

REGULAR MAINTENANCE

Details routine upkeep tasks like cleaning filters and cores.

ANNUAL MAINTENANCE

Outlines yearly service including cleaning and system checks.

TROUBLESHOOTING

Venmar 2.6 HE Specifications

General IconGeneral
Airflow Capacity260 CFM @ 0.2 in. w.g.
Airflow260 CFM
HVI CertifiedYes
ENERGY STAR CertifiedYes
Voltage120 V
Dimensions11.25" x 11.25" x 7.625"
Quiet operationYes
Low energy consumptionYes
Duct Size6 inches