© Venom Group International 2013
Incorrect polarity detected.
Battery connection was interrupted.
Short-circuit of the output termination
Input voltage wrong.
The charger has an internal error. Please contact Venom
customer service.
The voltage is lower than the setting currently selected.
Please check the number of cells in the battery pack.
Voltage in one cell in the pack is too low to charge safely.
Please check the voltages of each cell.
Voltage in one cell in the pack is too high to charge safely.
Please check the voltages of each cell.
Connector error. Please check the connections at the
battery and charger.
Internal temperature of the charger is too high. Allow time
for the charger to cool.
The processor cannot control the feeding current.
Contact Venom customer service.
The battery balance connector or charge leads are not
connected properly for IR testing. Please check your
connections and try again.
The battery balance port or the power line to connect is
incorrect.
Battery Pack IR
0m
1 : --- --- --- mΩ
4 : --- --- --- mΩ