EasyManua.ls Logo

Venstar T1700 User Manual

Venstar T1700
79 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Page 1 of 2
Rev. 20080213
Quick-Start Guide
INSTEON™ Thermostat Adapter, Totaline™ / Venstar™
Model: #2441V
INSTEON Thermostat Adapter
Introduction
The INSTEON Thermostat Adapter adds remote control and monitoring to 3
compatible models of Totaline
TM
/ Venstar
TM
brand thermostats. It simply
plugs into the bottom of compatible thermostats and communicates via
INSTEON RF giving you wireless remote control and monitoring from
anywhere in your home, or the world.
The 3 compatible models are:
1-Day Programmable Venstar Thermostat (30410A)
7-Day Programmable Venstar Thermostat (30411A)
7-Day Programmable, Dual-Fuel Venstar Thermostat (30412A)
Note: To use the above mentioned thermostats, make sure your install
location’s wiring has 5 wires or check with a local installer.
Installation
1) Simply plug the INSTEON Thermostat Adapter into the jack on the bottom of your thermostat
Green LED will turn on
Un-Install
1) Open the front cover of the thermostat by gently pulling the right edge of the cover towards you
2) While pressing firmly on the small round button (center, bottom of thermostat) pull down gently on the INSTEON Thermostat Adapter
INSTEON Thermostat Adapter will disconnect from the thermostat
Adding your Thermostat Adapter to a Scene on an INSTEON Compatible Controller
For example, let’s say you would like to remotely control your thermostat to 73 degrees, heat mode from the comfort and convenience of your couch,
using the Scene A button on your RemoteLinc (If you want to use another INSTEON Compatible Controller, see its user manual)
Note: Linking your Adapter to a scene allows your thermostat to go to a chosen setting.
Here, you will link your Scene A button to “recall” both the setpoints and mode of the thermostat.
1) Tap the mode button on your thermostat until the mode indicated is heat
2) Tap the up and/or down arrows on your thermostat until the temperature set point is 73 degrees
3) Press & hold the top of the Scene A button on your RemoteLinc (for about 10 seconds) until it beeps
LED will start blinking (Press & hold for 10 seconds works for just about every INSTEON-compatible Controller;
please check the controller’s owner’s manual if you need help)
4) Press & hold the button on the INSTEON Thermostat Adapter (for about 5 seconds)
LCD display on your thermostat will briefly display all its characters, then return to normal
INSTEON Adapter’s LED will blink off faintly, then return to steady on
RemoteLinc will beep and its LED will stop blinking
5) Tap the mode button on your thermostat (this will temporarily change the operating mode to allow you to test your remote control)
Your thermostat’s mode will change to cool
6) Now to test your new link, tap the Scene A (up arrow) on your RemoteLinc
Your thermostat should return to heat mode with a 73-degree set point
7) Repeat steps 1 through 6 for as many scenes and setpoints on your INSTEON-Compatible Controller as you wish.
Note: Sending an Off command will not change the mode or setpoints of the thermostat. These commands are ignored to minimize unintended results.
Note: Different set points can be linked to different buttons should you need more flexibility.
Button
LED

Other manuals for Venstar T1700

Question and Answer IconNeed help?

Do you have a question about the Venstar T1700 and is the answer not in the manual?

Venstar T1700 Specifications

General IconGeneral
ModelT1700
CategoryThermostat
ProgrammableYes
Hold FunctionYes
Filter Change AlertYes
Battery BackupNo
Temperature Control±1°F
TypeDigital
Stages2 Heat / 1 Cool

Summary

INSTEON Thermostat Adapter Quick Start

Introduction to INSTEON Thermostat Adapter

Overview of the INSTEON Thermostat Adapter and compatible models.

INSTEON Thermostat Adapter Installation and Un-Install

Steps for physically connecting and disconnecting the INSTEON Thermostat Adapter.

Adding INSTEON Adapter to INSTEON Scenes

Guide to linking the adapter to scenes for remote control and automation.

INSTEON Thermostat Adapter Operations

Removing INSTEON Adapter from INSTEON Scenes

Procedure to unlink the INSTEON Thermostat Adapter from a scene.

INSTEON Thermostat Adapter Factory Reset

Steps to restore the INSTEON Thermostat Adapter to its default factory settings.

Advanced Operations & FCC Statement

Overview of advanced uses and regulatory compliance information for the adapter.

Section 1 Preparation

Assemble Tools

Lists the necessary tools for thermostat installation.

Section 2 Remove & Replace the Old Thermostat

Section 3 Wire Connections

Section 4 Sample Wiring Diagrams

6 Wire, 1 Stage Cooling, 1 Stage Gas Heat Diagram

Wiring diagram for residential/commercial 1-stage cooling with 1st-stage gas heat.

6 Wire, 1 Stage Cooling, 1 Stage Electric Heat Diagram

Wiring diagram for residential/commercial 1-stage cooling with 1st-stage electric heat.

6 Wire, 1 Stage Cooling, 2 Stage Heat Diagram (Heat Pump w/ O Valve)

Wiring diagram for heat pump with O reversing valve, 1-stage cooling, 2-stage heat.

6 Wire, 1 Stage Cooling, 2 Stage Heat Diagram (Heat Pump w/ b Valve)

Wiring diagram for heat pump with b reversing valve, 1-stage cooling, 2-stage heat.

Installing the Outdoor Sensor

Instructions for connecting the outdoor sensor to the thermostat.

Section 5 Test Operation

Section 6 Calibrating the Thermostat Sensors

Section 7 Troubleshooting

Section 8 Thermostat Display Options

Turning On/Off the Backlight

Guide to adjusting the thermostat's display backlight settings.

Programming Temperature Display (Fahrenheit/Celsius)

How to set the thermostat to display temperature in F or C.

Locking/Unlocking the Keypad

Procedure to prevent unauthorized use by locking/unlocking the thermostat keypad.

Section 9 Programming Run-Time Alerts

Setting and Resetting the Service Filter Alert

How to set and reset the fan run-time alert for filter replacement.

Setting and Resetting the UV Light Alert

How to set and reset the UV light run-time alert.

Section 10 Electric Heat and Heat Pump Operation

Viewing Heat Pump and Reversing Valve Jumper Settings

How to check the thermostat's jumper settings for heat pump and reversing valve.

Viewing Electric Heat Jumper Setting

How to check the thermostat's jumper setting for electric heat operation.

Using Emergency Heat

Instructions for activating and deactivating the emergency heat feature.

Section 11 Timers and Deadbands

Adjusting the Heat/Cool Differential

Setting the minimum difference between heating and cooling setpoints.

Adjusting the Cycles Per Hour

Limiting the number of times the HVAC unit can energize per hour.

Adjusting the Deadband

Setting temperature thresholds for stage activation and turn-on.

Section 12 Factory Defaults and Calibration

Resetting the Thermostat to Factory Default Settings

Procedure to return all thermostat settings to their original factory defaults.

Calibrating Temperature and Humidity Sensors

Steps for calibrating the thermostat's internal temperature and humidity sensors.

Section 13 Accessories

Section 14 Advanced Setup Table

Section 16 Warranty