Vertex VXR-5000 - Set up; Penalty-Time; Hi Temp Pwr Red; Hang-Time Audio Sel

Vertex VXR-5000
136 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
from 1
~
60
sees.
or
disabled
by
pressing
the
SPACE bar.
Penal
ty-
Time
- this
determines
the re-
peater
"dead"
-
or
penalty-time after the
Time-Out Timer
has
expired before
any
station
can
access
the
repeater
again.
Timer is adjustable from
10
~
360 seconds.
Set Up
The following repeater system operation
can
be
programmed
according to user re-
quirements from this menu:
Mode
- Use
the
SPACE
bar
to toggle be-
tween
Simplex
or
Duplex
operation.
DC
RF PWR
LVL
-
When
operation shifts
to auxiliary DC
power
source, selecting
low
power
will result in
TX
power
auto-
matically switching to low
power
to ex-
tend
operation
time
under
battery power.
VXR-5000
Normal
selection retains
TX
power
at
the
default
power
setting
(as
set
in
the
align-
mentmode).
Hi
Te
mp
Pwr
Red
- This feature automat-
ically
monitors
repeater
TX
power
ampli-
fier
temperature,
and,
if safe
operating
temperatures
are
exceeded, reduces
TX
output
power
(or disables
the
transmitter)
to
prevent
damage
from over-heating.
Al
arm
Beeper
-
Enables/disables
the
Alarm
beep
tone
as
the
Time-Out Timer is
about
to expire.
Hang-Time
Audio
Sel
-
Determines
if
channel
audio
(noise) will
be
heard
during
TX
hang-time
(repeater
keyed
with
carrier
not
present). With Quiet selected, receiver
audio
will
remain
squelched, Noise-Out
enables
open-channel
noise
(muted
-10
dB) to
be
heard.
Use
the
SPACE
bar
to
make
a selection.
Repeater System
Configuration
Setup
Instruction
Manual
3-1