Lieber GXT3™
208V, 5000-10,000VA, 6000RTL630
Installer/User Guide
FOR HISTORICAL USE ONLY

Table of Contents

Questions and Answers:

Vertiv Liebert GXT3-8000RT208 Specifications

General IconGeneral
Product TypeUPS
Nominal Output Voltage208V
Input Voltage208V
Nominal Input Voltage208 V
Humidity0-95% non-condensing
ModelGXT3-8000RT208
TopologyDouble Conversion
Capacity8 kVA
Output Power Capacity8000VA / 8000W
Output Frequency50/60 Hz
Form FactorTower/Rackmount
Battery TypeSealed Lead Acid
Communication PortsUSB
Operating Temperature32 to 104°F (0 to 40°C)
Storage Temperature5 to 113°F (-15 to 45°C)

Summary

IMPORTANT SAFETY INSTRUCTIONS

5 INSTALLATION AND CONFIGURATION

5.1 Install the Main Cabinet

Guides installation of the main UPS cabinet in tower or rack configuration.

5.1.1 Tower UPS Installation

Step-by-step instructions for installing the UPS in a tower configuration.

5.1.2 Rack-Mount UPS Installation

Instructions for installing the UPS in a rack, requiring a slide kit or rails.

5.3 Connect Input/Output Power

Instructions for connecting input and output power to the UPS.

5.3.1 Remove the Power Distribution Box from 5000 and 6000VA Models

Steps to remove the power distribution box from specific UPS models.

5.3.2 Remove the Power Distribution Cover from 8000 and 10,000VA Models

Steps to remove the power distribution cover from other UPS models.

6 CONFIGURATION PROGRAM

6.1 Configuration Program Features

Lists various features configurable via the program, like voltages, restart, and alarms.

7 CONTROLS AND INDICATORS

8 OPERATION

8.1 Startup Checklist for the Liebert GXT3

Lists pre-startup checks for the UPS.

8.2 Initial Startup and Electrical Checks

Guides through the initial startup and electrical checks before full operation.

9 COMMUNICATION

10 MAINTENANCE

10.1 Replacing the Internal Battery Pack

Step-by-step guide for safely replacing the internal battery pack.

10.1.1 Battery Replacement Procedures

Detailed steps for removing and replacing the UPS internal battery packs.

10.3 Precautions

Safety precautions to observe during maintenance and cleaning.

10.6 Replacing the Power Module

CAUTION about switching to manual bypass before replacing the power module.

11 TROUBLESHOOTING

11.1 UPS Symptoms

Lists common symptoms indicating a UPS malfunction.

11.1.1 Indicators

Explains the diagnostic aid provided by illuminated LED segments on the battery indicator.

11.1.2 Audible Alarm

Describes audible alarms and their correlation with visual indicators.

11.2 Troubleshooting

A table guiding users to determine causes and solutions for UPS issues.