Vertiv Liebert GXT5-3000LVRT2UXL - User Manual

Vertiv Liebert GXT5-3000LVRT2UXL
94 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Liebert®
GXT5 UPS
208 V Input, 208 V Output, L1-L2-G
HV
Installer/User Guide

Table of Contents

Other manuals for Vertiv Liebert GXT5-3000LVRT2UXL

Questions and Answers

  • P
    Patrick AndersenAug 9, 2025
    Why does my Vertiv UPS have reduced battery backup time?
    • A
      Andrew JohnsonAug 9, 2025
      If your Vertiv UPS has reduced battery backup time, ensure it's plugged in continuously for at least 24 hours to recharge the batteries. Also, check the load level indicator and reduce the load if the UPS is overloaded. If the batteries are old, consider replacing them. Contact your Vertiv representative or Vertiv Technical Support for a replacement battery kit.
  • D
    Daniel FoleyAug 29, 2025
    What to do if my Vertiv UPS fails to start?
    • S
      Sarah FlowersAug 29, 2025
      If your Vertiv UPS fails to start, it might be due to a short circuit or overload. Turn off the UPS, disconnect all connected devices, and ensure nothing is stuck in the output receptacles. Also, verify that the connected devices are not faulty or shorted internally. Alternatively, the batteries may not be adequately charged or properly connected. Check the internal battery connection and connect it if necessary. If the battery is already connected, allow the UPS to charge for 24 hours by keeping it connected to the input power before attempting to start it again.
  • T
    Tyler GillSep 10, 2025
    What to do if Vertiv UPS fails to start?
    • J
      Jamie LopezSep 12, 2025
      If your Vertiv UPS fails to start, it might be short-circuited or overloaded. Ensure the UPS is off, disconnect all loads, and check for obstructions in the output receptacles. Also, verify that the connected loads are not defective or shorted internally. Alternatively, the batteries may not be charged or properly connected. Check the internal battery connection and connect it if necessary. If connected, leave the UPS connected to input power for 24 hours to recharge before attempting to start it.

Summary

Important Safety Information

Chapter 1: GXT5 Description

1.6. Major Internal Components and Operating Principle

Explains the UPS operating principle and lists major components.

Chapter 2: Installation

2.3. Installing the UPS

Instructions for installing the UPS in tower or rack configurations.

2.3.1. Tower Installation

Steps for installing the UPS in a tower configuration.

2.3.2. Rack Installation

Steps for installing the UPS in a rack configuration.

2.6. Hardwired Input;Output Connections

Guidelines for making hardwired input and output electrical connections.

2.6.1. Branch Circuit Breaker

Details requirements for branch circuit breakers.

2.7.3. Connecting a Remote Emergency Power-off (REPO) Switch

How to connect a REPO switch for emergency shutdown.

2.8. Installing a Parallel System

Options and requirements for setting up a parallel UPS system.

2.8.1. First-time Start-up of a Parallel System

Procedure for the initial startup of a parallel UPS system.

2.8.2. Commissioning Parallel System

Steps to commission a parallel UPS system.

Chapter 3: Operating the UPS

3.2. Starting-up the UPS

Step-by-step guide to starting up the UPS.

3.6. Shutting-down the UPS Completely

Steps to completely shut down the UPS.

3.7. Remote Emergency Power-off (REPO)

How REPO functions to shut down the UPS in emergencies.

Chapter 4: Operation and Display Panel

4.2.4. Settings Submenu

Navigating the settings menu for configuration.

4.2.5. Control Screen

Options for controlling UPS operations like start/stop, alarms.

4.3. Editing Display and Operation Settings

Procedures for changing display and operation settings.

4.3.2. Changing the Password

Steps to change the default password.

Chapter 5: Maintenance

5.1. Replacing Batteries

Safety precautions and steps for replacing batteries.

5.6. Firmware Updates

Overview of firmware updates and file names.

Chapter 6: Troubleshooting

6.3. Troubleshooting UPS Issues

Guide to determine cause and solution for UPS issues.

Appendix I: Technical Support

Vertiv Liebert GXT5-3000LVRT2UXL Specifications

General IconGeneral
Product TypeUPS
Power Rating3000VA
Output Power Capacity2700W
TopologyDouble Conversion Online
Input Frequency40-70 Hz
Output Power Factor0.9
EfficiencyUp to 95%
Efficiency Online ModeUp to 95%
Rack Height2U
Output Frequency50/60 Hz
Form FactorRack/Tower
Battery TypeSealed Lead Acid
Communication PortsUSB, RS-232
Weight66.1 lbs
Operating Temperature32°F to 104°F (0°C to 40°C)
Operating Humidity0% to 95% non-condensing