Vertiv Liebert GXT5-500LVRT2UXLN - User Manual

Vertiv Liebert GXT5-500LVRT2UXLN
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Liebert®
GXT5™ UPS
120 V Input, 120 V Output
LV
Installer/User Guide

Table of Contents

Questions and Answers

  • A
    angela59Aug 11, 2025
    Why does my Vertiv UPS have reduced battery backup time?
    • B
      Brian ParkerAug 11, 2025
      If your Vertiv UPS has reduced battery backup time, ensure it's plugged in continuously for at least 24 hours to recharge the batteries. Also, check the load level indicator and reduce the load if the UPS is overloaded. If the batteries are old, consider replacing them. Contact your Vertiv representative or Vertiv Technical Support for a replacement battery kit.
  • J
    Jessica SchmittAug 21, 2025
    What to do if Vertiv UPS fails to start?
    • C
      Crystal CooperAug 22, 2025
      If your Vertiv UPS fails to start, it might be short-circuited or overloaded. Ensure the UPS is off, disconnect all loads, and check for obstructions in the output receptacles. Also, verify that the connected loads are not defective or shorted internally. Alternatively, the batteries may not be charged or properly connected. Check the internal battery connection and connect it if necessary. If connected, leave the UPS connected to input power for 24 hours to recharge before attempting to start it.
  • T
    Troy MartinAug 31, 2025
    What to do if my Vertiv UPS fails to start?
    • M
      Michael ContrerasAug 31, 2025
      If your Vertiv UPS fails to start, it might be due to a short circuit or overload. Turn off the UPS, disconnect all connected devices, and ensure nothing is stuck in the output receptacles. Also, verify that the connected devices are not faulty or shorted internally. Alternatively, the batteries may not be adequately charged or properly connected. Check the internal battery connection and connect it if necessary. If the battery is already connected, allow the UPS to charge for 24 hours by keeping it connected to the input power before attempting to start it again.

Vertiv Liebert GXT5-500LVRT2UXLN Specifications

General IconGeneral
Frequency50/60 Hz
TopologyDouble Conversion Online
Output Frequency50/60 Hz
Battery TypeSealed Lead Acid
Typical Backup Time15-30 minutes (varies by battery configuration)
Form FactorTower
Communication PortsRS-232, USB
SNMP SupportYes (with optional network card)
Operating Temperature0 to 40°C (32 to 104°F)
Input Frequency50/60 Hz
Waveform TypePure Sine Wave
Battery Recharge Time3 hours to 90%
Storage Temperature-15 to 40°C (5 to 104°F)