Liebert®
GXT5 UPS
208 V Input, 208 V Output, L1-L2-G
HV
Installer/User Guide

Table of Contents

Other manuals for Vertiv Liebert GXT5-2000LVRT2UXL

Questions and Answers

  • B
    Brian StewartAug 9, 2025
    Why does my Vertiv UPS have reduced battery backup time?
    • L
      Larry RamirezAug 9, 2025
      If your Vertiv UPS has reduced battery backup time, ensure it's plugged in continuously for at least 24 hours to recharge the batteries. Also, check the load level indicator and reduce the load if the UPS is overloaded. If the batteries are old, consider replacing them. Contact your Vertiv representative or Vertiv Technical Support for a replacement battery kit.
  • J
    Joseph ScottAug 18, 2025
    What to do if Vertiv Liebert GXT5-2000LVRT2UXL UPS fails to start?
    • A
      Ann DudleyAug 18, 2025
      If your Vertiv UPS fails to start, it might be short-circuited or overloaded. Ensure the UPS is off, disconnect all loads, and check for obstructions in the output receptacles. Also, verify that the connected loads are not defective or shorted internally. Alternatively, the batteries may not be charged or properly connected. Check the internal battery connection and connect it if necessary. If connected, leave the UPS connected to input power for 24 hours to recharge before attempting to start it.
  • J
    johnsonelijahAug 28, 2025
    What to do if my Vertiv UPS fails to start?
    • J
      Joshua SandovalAug 28, 2025
      If your Vertiv UPS fails to start, it might be due to a short circuit or overload. Turn off the UPS, disconnect all connected devices, and ensure nothing is stuck in the output receptacles. Also, verify that the connected devices are not faulty or shorted internally. Alternatively, the batteries may not be adequately charged or properly connected. Check the internal battery connection and connect it if necessary. If the battery is already connected, allow the UPS to charge for 24 hours by keeping it connected to the input power before attempting to start it again.

Summary

Important Safety Information

Chapter 1: GXT5 Description

1.6. Major Internal Components and Operating Principle

Explains the function of the UPS's major internal components and its basic operating principle.

1.7. UPS States and Operating Modes

Outlines the different operating states and modes of the UPS system.

Chapter 2: Installation

2.1. Unpacking and Inspection

Provides steps for unpacking the UPS and conducting initial inspections for damage.

2.2. Pre-installation Preparation

Outlines essential preparation steps for UPS installation, including environmental considerations.

2.3. Installing the UPS

Provides instructions for installing the UPS in either a tower or rack configuration.

2.3.1. Tower Installation

Step-by-step guide for installing the UPS in a vertical tower orientation.

2.3.2. Rack Installation

Instructions for mounting the UPS within a standard rack enclosure.

2.4. Installing External Battery Cabinets

Details how to connect and install optional external battery cabinets for extended runtime.

2.5. Installing a Power distribution Box

Procedures for installing a power distribution box (POD) for electrical connections.

2.6. Hardwired Input;Output Connections

Guidelines and specifications for making hard-wire input and output connections to the UPS.

2.6.2. Terminal-block Connections

Specifications and procedures for making electrical connections via terminal blocks.

2.7. Communication Connections

Overview of available communication interfaces and ports on the UPS.

2.7.3. Connecting a Remote Emergency Power-off (REPO) Switch

Procedure for connecting a REPO switch to provide emergency shutdown capability.

2.8. Installing a Parallel System

Details on configuring the 10-kVA model for parallel UPS system operation.

2.8.1. First-time Start-up of a Parallel System

Step-by-step guide for the initial startup and parameter synchronization of a parallel UPS system.

2.8.2. Commissioning Parallel System

Procedures for commissioning a parallel UPS system after installation and setup.

2.8.3. Adding a Single UPS to the Parallel System

Instructions for adding or replacing a UPS unit within an existing parallel system.

Chapter 3: Operating the UPS

3.2. Starting-up the UPS

Detailed steps for powering on the UPS after installation and commissioning.

3.3. Transferring to Battery Mode

Explains how the UPS automatically transfers to battery power during utility outages.

3.4. Transferring from Normal to Bypass Mode

Procedure for manually switching the UPS output from normal inverter operation to bypass.

Chapter 4: Operation and Display Panel

Chapter 5: Maintenance

5.1. Replacing Batteries

Detailed instructions and safety precautions for replacing the UPS battery packs.

Chapter 6: Troubleshooting

6.3. Troubleshooting UPS Issues

Provides a guide to diagnose and resolve common UPS problems and issues.

Vertiv Liebert GXT5-2000LVRT2UXL Specifications

General IconGeneral
Product TypeUPS
TopologyDouble Conversion Online
Power Capacity2000 VA
Output Power1800 W
Input Frequency40-70 Hz
Output Voltage Regulation± 1%
Runtime at Full Load5 minutes
Form FactorRack/Tower
Rack Height2U
Management InterfaceLCD Display
Communication PortsUSB, RS-232
SmartSlotYes
Operating Humidity0% to 95% (Non-Condensing)
Output Frequency50/60 Hz
Battery TypeSealed Lead Acid
Runtime at Half Load15 minutes
Outlets8
Operating Temperature32°F to 104°F (0°C to 40°C)