EasyManua.ls Logo

Vertiv Liebert GXT5-6000IRT5UXLE User Manual

Vertiv Liebert GXT5-6000IRT5UXLE
117 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Liebert®
GXT5™ UPS
230 V Input, 230 V Output
I
Installer/User Guide

Table of Contents

Other manuals for Vertiv Liebert GXT5-6000IRT5UXLE

Question and Answer IconNeed help?

Do you have a question about the Vertiv Liebert GXT5-6000IRT5UXLE and is the answer not in the manual?

Vertiv Liebert GXT5-6000IRT5UXLE Specifications

General IconGeneral
ModelGXT5-6000IRT5UXLE
Product TypeUPS
TopologyDouble Conversion Online
Power Rating6000VA
Output Power Capacity6000VA / 6000W
Input Voltage200-240 VAC
Output Voltage Regulation+/- 1%
Output Power Factor1.0
Output WaveformSinewave
Typical Recharge Time3 hours to 90%
Form FactorRack/Tower
Rack Size5U
Humidity0-95% non-condensing
Input Frequency40-70 Hz
Output Frequency50/60 Hz
Battery TypeSealed Lead-Acid (SLA)
RuntimeVaries with load
Communication PortsUSB, RS-232
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-15°C to 45°C (5°F to 113°F)
Weight132.28 lbs (60 kg)

Summary

Important Safety Information

GXT5 Product Description

UPS Features and Available Models

Lists available models and power ratings, detailing key product features.

Internal Battery Packs

Details the location and types of internal battery packs used in the UPS.

Major Internal Components and Operating Principle

Explains the core internal components and how the UPS operates.

UPS States and Operating Modes

Normal Mode

Describes normal operation where UPS provides stabilized power using rectifier and inverter.

Bypass Mode

Explains bypass mode where UPS supplies power from bypass source (utility power).

Installation

Installing the UPS

Guides the user through the process of installing the UPS unit.

Hardwired Input/Output Connections

Details on making hardwired electrical connections for UPS input and output.

Communication Connections

Connecting a Remote Emergency Power-off (REPO) Switch

Procedure for connecting a REPO switch to shut down the UPS in emergencies.

Installing a Parallel System

First-time Start-up of a Parallel System

Steps for the initial start-up and parameter setup of a parallel UPS system.

Commissioning Parallel System

Procedure for commissioning and verifying a parallel UPS system's operation.

Operating the UPS

Starting-up the UPS

Procedure for starting up the UPS unit safely.

Shutting-down the UPS Completely

Steps for completely shutting down the UPS unit.

Remote Emergency Power-off (REPO)

How the REPO function works to turn off the UPS in emergency conditions.

Operation and Display Panel

Settings Submenu

Explains how to access and modify UPS settings via the menu.

Editing Display and Operation Settings

Changing the Password

Procedure for changing the UPS display and operation settings password.

Maintenance

Replacing Batteries

Detailed procedure for safely replacing the UPS internal battery packs.

Firmware Updates

Updating Firmware with RDU101 Card Connection

Steps to update firmware using the RDU101 communication card.

Updating DSP Firmware via RDU101

Procedure to update DSP firmware using the RDU101 communication card.

Updating Firmware with a CLI Connection

Procedure to update firmware using Command Line Interface (CLI).

Troubleshooting

Troubleshooting UPS Issues

Specifications