  • W
    wardnathanielAug 9, 2025
    Why does my Vertiv Liebert GXT5-1500LVRT2UXL UPS have reduced battery backup time?
    • M
      mercerjaredAug 9, 2025
      If your Vertiv UPS has reduced battery backup time, ensure it's plugged in continuously for at least 24 hours to recharge the batteries. Also, check the load level indicator and reduce the load if the UPS is overloaded. If the batteries are old, consider replacing them. Contact your Vertiv representative or Vertiv Technical Support for a replacement battery kit.
  • M
    Marissa VillaAug 19, 2025
    What to do if Vertiv UPS fails to start?
    • N
      nguyenjenniferAug 19, 2025
      If your Vertiv UPS fails to start, it might be short-circuited or overloaded. Ensure the UPS is off, disconnect all loads, and check for obstructions in the output receptacles. Also, verify that the connected loads are not defective or shorted internally. Alternatively, the batteries may not be charged or properly connected. Check the internal battery connection and connect it if necessary. If connected, leave the UPS connected to input power for 24 hours to recharge before attempting to start it.
  • G
    Garrett GouldAug 28, 2025
    What to do if my Vertiv Liebert GXT5-1500LVRT2UXL UPS fails to start?
    • J
      Julie HullAug 28, 2025
      If your Vertiv UPS fails to start, it might be due to a short circuit or overload. Turn off the UPS, disconnect all connected devices, and ensure nothing is stuck in the output receptacles. Also, verify that the connected devices are not faulty or shorted internally. Alternatively, the batteries may not be adequately charged or properly connected. Check the internal battery connection and connect it if necessary. If the battery is already connected, allow the UPS to charge for 24 hours by keeping it connected to the input power before attempting to start it again.

Summary

Important Safety Information

Chapter 2: Installation

2.1. Unpacking and Inspection

Instructions for unpacking the UPS and performing initial checks for damage and completeness.

2.2. Pre-installation Preparation

Guidelines for preparing the installation environment and site for the UPS, including clearances.

2.3. Installing the UPS

Procedures for installing the UPS in either a tower or rack configuration.

2.6. Hardwired Input;Output Connections

Guidelines for making hard-wire input and output electrical connections for the UPS.

2.8. Installing a Parallel System

Requirements and procedures for configuring and commissioning parallel UPS systems.

Chapter 3: Operating the UPS

3.2. Starting-up the UPS

Step-by-step guide for powering on the UPS after installation.

3.6. Shutting-down the UPS Completely

Instructions for safely powering down the UPS completely.

3.7. Remote Emergency Power-off (REPO)

How the REPO function works and how to manually trigger an emergency shutdown.

Chapter 5: Maintenance

5.1. Replacing Batteries

Detailed procedure for replacing the internal battery packs of the UPS.

Chapter 6: Troubleshooting

6.3. Troubleshooting UPS Issues

Provides a guide to identify causes and solutions for common UPS operational issues.

Vertiv Liebert GXT5-1500LVRT2UXL Specifications

General IconGeneral
ModelGXT5-1500LVRT2UXL
TypeOnline Double Conversion
TopologyDouble Conversion
Capacity1500VA / 1350W
Output Frequency50/60 Hz ± 0.1%
Form FactorRack/Tower
Rack Height2U
Operating Temperature32°F to 104°F (0°C to 40°C)
Input Frequency40 Hz - 70 Hz
Battery TypeSealed Lead-Acid (SLA)
CommunicationUSB, RS-232