Vertiv Liebert GXT5-10KIRT5UXLE User Manual

Vertiv Liebert GXT5-10KIRT5UXLE
117 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Liebert®
GXT5™ UPS
230 V Input, 230 V Output
I
Installer/User Guide

Table of Contents

Other manuals for Vertiv Liebert GXT5-10KIRT5UXLE

Question and Answer IconNeed help?

Do you have a question about the Vertiv Liebert GXT5-10KIRT5UXLE and is the answer not in the manual?

Vertiv Liebert GXT5-10KIRT5UXLE Specifications

General IconGeneral
ModelLiebert GXT5-10KIRT5UXLE
Product TypeUPS
TopologyDouble Conversion Online
Capacity10 kVA / 10 kW
Output Voltage200/208/220/230/240 VAC
Rack Size5U
Output Power Factor1.0
Input Voltage200/208/220/230/240 VAC
Output Voltage THD< 3%
Input Frequency40 Hz to 70 Hz
Output Frequency50 Hz / 60 Hz (Selectable)
Form FactorRack/Tower
Battery TypeSealed Lead-Acid (SLA)
Communication PortsUSB, RS-232
Operating Temperature0°C to 40°C
Storage Temperature-15°C to 45°C
Humidity0-95% (non-condensing)

Summary

Important Safety Information

Chapter 2: Installation

Chapter 3: Operating the UPS

3.2. Starting-up the UPS

Step-by-step guide to safely start the UPS after installation and commissioning.

Chapter 4: Operation and Display Panel

1.7. Major Internal Components and Operating Principle

2.4. Installing External Battery Cabinets

2.6. Hardwired Input/Output Connections

2.6.2. Terminal-block Connections

2.7.3. Connecting a Remote Emergency Power-off (REPO) Switch

2.8. Installing a Parallel System

CAUTION! Risk of improper disconnection

Caution against disconnecting parallel system cables while operating.

2.8.1. First-time Start-up of a Parallel System

2.8.2. Commissioning Parallel System

2.8.3. Adding a Single UPS to the Parallel System

CAUTION

Caution to ensure correct cabling before powering on an added/replacement UPS.

3.6. Shutting-down the UPS Completely

3.7. Remote Emergency Power-off (REPO)

4.2.4. Settings Submenu

System Parameter Options

4.3. Editing Display and Operation Settings

4.3.2. Changing the Password

Chapter 5: Maintenance

WARNING! Risk of electric shock

Critical warning about electric shock and short-circuit hazards when working with batteries.

WARNING! Risk of electric shock and explosion

Warning about explosion risk and hazards from battery disposal or damage.

5.6. Firmware Updates

5.6.1. Updating Firmware with RDU101 Card Connection

Step-by-step guide to update firmware using an RDU101 communication card.

Updating MCU Firmware via RDU101

5.7. Updating DSP Firmware via RDU101

5.8. Updating Firmware with a CLI Connection

Updating DSP Firmware via CLI

Chapter 6: Troubleshooting

6.3. Troubleshooting UPS Issues

Chapter 7: Specifications

7.1. Battery Run Times

Appendix II: Technical Support

Related product manuals