06
TECHNICAL SPECIFICATION
Line Input Power
Current
Circuit Breaker Rating
Power Draw at Idle
EV Charging Plug
Operating Temperature
Power Plug
Cable Length
Model
Protection Level
Charging Protection
Certicate
Weight
Type 2 Portable Charger
110-240V
32A/24A/20A/16A/10A
40 amps@240v
< 2 watts
IEC 62196 Type 2
-13°F to 122°F / -25°C to 50°C
CEE
7.5 m
3.5 kg
CE / RoHS
Over-current protection, over-voltage protection,
under-voltage protection, leakage protection,
and overheat protection integrated.
IP54 for the Type 2 plug and IP66 for the controller box
LED 4 Red
indicator
ashes 6 times
every 2
seconds
Above
temperature
limit Cases:
1. Temperature
is too high. The
charger will
restart charging
when it cools
down.
2. House/socket
wiring may be
faulty.
1. Inspect charger for overheating (hot to
the touch >85°C).
Charging will naturally restart once the
temperature returns to under 65°C.
a. Carefully unplug the portable charger
from the wall outlet and allow to cool.
b. If the condition persists, contact
support for assistance.
2. Disconnect the portable charger from
the wall outlet.
3. Have a qualied electrician inspect the
integrity of the wall outlet.
E-mail: CustomerService@vevor.com
Distributor name: Shanghai Sishun e-commerce Co., Ltd
Manufacturer: Jiangsu Yihang Electric Science and Technology Co., Ltd
Address: No. 262 DEYU road, Hongshan street, Xinwu district, Wuxi, Jiangsu,
214145 China
EC REP: EUREP GmbH
Unterlettenweg 1a, 85051 Ingolstadt Germany
eurep@eurep-gmbh.com
+49 841 8869 7744
Made in China