- 18 -
The displayed
water temp is
different from the
actual water temp
There is tolerance
between the LCD
displayed temp and the
actual water temp.
To calibrate water temperature:
1. Press and hold SET for 10 seconds to
enter Temp Error Adjustment Function,
digital display will show CA”.
2. Press "▲"(turn up) or "▼" (turn down)
until the displayed figure equals to the
tolerance intended to eliminate (tolerance
CA = actual water temp - displayed water
temp), adjusting range is +4 to -4.
3. After your adjusting operation has
stopped for 10 seconds, the control panel
will exit to show the adjusted temperature.
Water temp
reaching set-up
temp, but the unit
continues to run
Temperature sensor
not installed at right
place, or temperature
sensor failed
Turn off or replace the heating switch; refer
to operating instructions to adjust
temperature control.
Digital display
shows “E1”,
cannot detect
water temp
Check the temperature sensor installation.
Note: If any other abnormal conditions occur during normal use, please do not try to
dissemble and fix the machine by yourself, take it to your supplier or contact certificated
and licensed technicians for repair.