WARN
Although the average working current of the chiller is small, the instantaneous working current can sometimes
reach 6~10 amperes (the instantaneous working current of the AC110V power supply model is possible up to
10~1 5 amperes)
PLEASE MAKE SURE THAT THE POWER SUPPLY AND THE POWER OUTLET ARE IN GOOD CONTACT
AND THE GROUNDING WIRE MUST BE FIRM!
PLEASE MAKE SURE THAT THE WORKING CHILLER HAS A STABLE AND NORMAL VOLTAGE!
Since the refrigeration compressor is more sensitive to power supply and voltage, so the working voltage our
standard product is 220^ 240V (110V model is 110 120V), if you really need a wider operating voltage range,
we can customize.
PLEASE MISMATCHED POWER FREQUENCY WILL CAUSE CHILLER DAMAGE!
Please select mode: 50Hz or 60Hz depending on the actual situation.
TO PROTECT THE PUMP, IT IS STRICTLY FORBIDDEN TO RUN THE CHILLER WITHOUT WATER IN THE
STORAGE TANK!
The new machine is packed after draining the entire water in the tank, so please make sure that the tank has
enough water and there is water inside the machine before starting, otherwise it is easy to damage the pump.
When the water level is below the green (normal) range of the water level gauge, the cooling capacity of our
chillers will drop slightly. Therefore, make sure that the water level is in the green (normal) range. Pumps are
strictly forbidden by circulating drainage!
PLEASE MAKE SURE THE AIR INLET AND OUTLET ARE WELL VENTILATED!
The air outlet from the obstacle to the back of the cooler must be at least 30 cm, and it should be at least 8 cm
between the obstacle and the side air intake.
THE FILTER MUST BE CLEANED REGULARLY!
The dust meter must be unlocked and cleaned, otherwise it will cause serious clogging failure to the cooler.
PAY ATTENTION TO THE EFFECT OF CONDENSATE!
As the ambient humidity increases, when the water temperature is lower than the ambient temperature,
condensate will create circular pipes and cooling parts on the water surface. If this occurs, it is recommended
to set a higher water temperature or keep the connected pipes and cooling components warm.
PROFESSIONAL USE ONLY!
This device must not be used by a child or a person with physical, sensory or physical, sensory, or physical
impairments, or lack of experience and knowledge, unless supervision or instruction is given, and the child is
not allowed to play with electrical appliances!
The circulating water of the water cooler must use a sealed container for normal use, such as laser tube cooling
water. Unsealed containers cannot circulate, such as water basins, buckets cannot be used for circulating
water cooling with water coolers.
-2-