MANUAL VIAVAC-CB4 / 4.1 ( Expert section ) Art. nr. 50504 EN (01-07-2017)
__________________________________________________________________________________________
4
___________________________________________________________________________________
VIAVAC vacuum lifting BV T. + 31 348 449 660 E. info@viavac.com I. www.viavac.com
Compulsory a regular inspection of the device must also take place.
This in accordance with the requirements from the authorities of the country where the device is used.
In the device there are no pivoting points or parts which require lubrication.
The vacuum pump is completely maintenance free and lubrication is not allowed.
In vertical position of the suction pad, the load is held by the friction between the rubber back plate
of the suction pad and the load; therefore it is essential that this is clean, dry and oil-free.
Monthly cleaning of the rubber back plate with natural vinegar ensures that the required friction
between suction pad and the load remains retained.
Never use solvents, petrol or other chemical agents to clean the rubber of the suction pad.
Checks and repairs must be documented in writing; for this purpose the following forms can be
found in this manual:
- C 4 Check and maintenance report.
- C 11 Maintenance history.