MANUAL VIAVAC-CB4 / 4.1 ( Expert section ) Art. nr. 50504 EN (01-07-2017)
__________________________________________________________________________________________
7
___________________________________________________________________________________
VIAVAC vacuum lifting BV T. + 31 348 449 660 E. info@viavac.com I. www.viavac.com
Continuation from previous page
APPROVED
Limited value A D M Y 3Y
Control of vacuum pump
Switching on at vacuum level -0.65 bar +/- 2% - O O O
Time for switching off 10 sec after reaching vacuum level -0.65 bar +/- 2 sec. - O O O
Vacuum level after switching off min. 70% - O O O
Sealed condition
Decrease of vacuum in non-sucked state max. 3 % in 60 sec. - O O O
Decrease of vacuum level with wall panel suction pads in sucked state max. 10 % in 60 sec. - O O O
Decrease of vacuum level with roof panel extension set in sucked state max. 10 % in 60 sec. - O O O
Vacuum indicator
Compare level of vacuum indicator with digital vacuum switch +/- 0.03 bar O O O O
Battery
Capacity test min. 85% of 55Ah - - O O
Replace preventative - - - O
Charging current of battery charger min. 13V - - O O
Level indicator (Voltmeter) max. 1V difference - - O O
Tests O
Static load test 2x working load - - O O
Holding time test min. 5 minutes - - O O
Stickers
Presence of all stickers present - - O O
In readable condition - - O O
Instruction manual O
In readable condition - - O O
Approval
Fill in this inspection and maintenance report and undersign for approval. - - O O
Fill in the maintenance record of the instruction manual. - - O O
When everything is approved, apply new certification sticker with date indication. - - O O
____________________________________________________________________________________________________________________________
Remarks (A = Available / D = Daily / M = Monthly / J = Yearly / 3 Yearly)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Inspection & maintenance
executed by : _________________________________ Valid till : __________________