EasyManuals Logo

Viavi T-BERD 5800 Quick Card

Viavi T-BERD 5800
6 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
VIAVI Solutions
Quick Card
T-BERD/MTS 5800 Network Tester
Testing VOIP SIP Trunks
This document outlines how to connect the T-BERD/MTS to a Session Border Controller (SBC) and run
an Ethernet VOIP Terminate test to validate the provisioning and performance of a SIP trunk.
Equipment Requirements:
T-BERD/MTS 5800v2 or T-BERD 5800-100G equipped with the
following:
o BERT software release V26.1 or greater
o Test options:
C5VOIP: Voice over IP option
C5LSCAPTURE (recommended for packet capture/decode)
CAT5E or optical jumper cables to match the line under test
Headset (Plantronics M114 or M210c recommended)
For optical interfaces:
o Fiber inspection microscope
(VIAVI P5000i or FiberChek Probe)
o Fiber optic cleaning supplies
Figure 1: Equipment Requirements
The following information is required to complete the test:
Physical Interface (RJ-45 Copper, 1000BASE-SX Multimode, 1000BASE-LX Single mode, etc.)
Speed and Auto Negotiation settings of the SBC LAN port
VLAN ID (if a VLAN is being used)
IP Address for the SBC LAN port
IP Address, Subnet mask, and default gateway for the T-BERD/MTS or PBX
Is registration required, or is this a non-registering trunk?
User Name and Password (required for registering trunks only)
Customer’s Billing Telephone Number for the SIP trunk
Destination Telephone Number(s) for outbound call testing
Connect to Line Under Test:
For copper testing with the T-BERD/MTS 5800v2, connect the Port 1 10/100/1000 RJ-45 jack to the
Ethernet port under test using CAT 5E or better cable, and proceed to page 2.
For copper testing with the T-BERD/MTS 5800-100G, connect the Port 2 10/100/1000 RJ-45 jack to
the Ethernet port under test using CAT 5E or better cable, and proceed to page 2.
For optical testing, insert an SFP or SFP+ into the Port 1 slot on the top of the T-BERD/MTS.
o Ensure the fiber and connectors are clean using a Fiber Inspection microscope.
o Connect the SFP or SFP+ to the Ethernet port under test.
Use CAT 5E or better cable for 10/100/1000BASE-T.
Use Multimode jumper cables for 850 nm 1000BASE-SX or 10GBASE-SR.
Use Single mode jumper cables for 1310 nm 1000BASE-LX or 10GBASE-LR.

Other manuals for Viavi T-BERD 5800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Viavi T-BERD 5800 and is the answer not in the manual?

Viavi T-BERD 5800 Specifications

General IconGeneral
BrandViavi
ModelT-BERD 5800
CategoryNetwork Cable
LanguageEnglish

Related product manuals