6.4 STEAM FLOW ADJUSTMENT
Use the dial to increase/reduce the flow of steam inject-
ed into the milk, as illustrated in the following figure.
6.5 ADJUSTING THE TURBOCREAM
NOZZLE
(If Fitted)
To increase/reduce the amount of air injected into the
milk from the TurboCream nozzle (and therefore to
increase/reduce the amount of foam in the heated milk)
proceed as illustrated in
Fig. 19:
0 Loosen the stainless steel tube (1) as illustrated in
Fig. 19.A.
1 To increase/reduce the amount of air, tighten (turn-
ing clockwise) or loosen (turning anticlockwise) the
Teflon tube (2) as illustrated in Fig. 19.B.
2 Tighten the stainless steel tube again.
E
NOTE
By reducing or increasing the length (tightening or
loosening) the tube/Teflon tube by a few fractions of a
mm/mm, there is a significant difference in the amount
of foam in the heated milk.
2
1