57
ENGLISH
will read:
GRINDING.
XXX
Using the▲ ▼ keys, itis possible toselect
XXX as:
NOT ACTIVE (pouring times will not be
shown).
ROW 1 (pouring times will be shown in row 1.
ROW 2 (pouring times will be shown in row 2).
• Press ENTER to confirm and pass to the
next step.
• Press RESET to return to the previous page
without confirming.
If the delivery time display is on when a
delivery is started - unless with the
Continuous function - the bottom line of the
display will show the delivery time (or times
if more than one unit is delivering).
Each group has an area of the bottom line:
the area on the left is for unit 1; the area
alongside it is for unit 2 and so on, until the
area on the far right, which is for unit 4.
The different areas are separated by vertical
bars; if a group is not delivering, the area is
empty.
Here below is an example: unit 1 is deliver-
ing (it has just started and 0 seconds have
passed); unit 2 has been delivering for 12
seconds and unit 4 is delivering (it has been
delivering for 21 seconds).
Thursday 12:00
0 I 12 I I 21
Area reserved to the
delivery time of unit 1
Area reserved to the
delivery time of unit 4
Area reserved to the
delivery time of unit 2
Area reserved to the
delivery time of unit 3
SETTING THE SET POINT PRESS
The SETPOINT PRESS: allows to chose the
pressure/ temperature in the working status.
SETPOINT PRESS
When the
ENTER
key is pressed, the display
will read:
SETPOINT PRESS
XX.XX BAR
Press ▲ ▼ to adjust the work-press/temp
point.
Press ENTER to confirm and pass to the
next step.
Press RESET to return to the previous page
without confirming.
PRESSURE - TEMPERATURE TABLE
Bar °C °F
0,50 110,5 230,9
0,55 111,5 232,7
0,60 112,5 234,5
0,65 113,5 236,3
0,70 114 237,2
0,75 115 239
0,80 115,5 239,9
0,85 116,5 241,7
Bar °C °F
0,90 117,5 243,5
0,95 118 244,4
1,00 119 246,2
1,05 119,5 247,1
1,10 120,5 248,9
1,15 121 249,8
1,20 122 251,6
1,25 112,5 252,5
1,30 123 253,4
1,35 124 255,2
1,40 124,5 256,1
1,45 125 257
1,50 126 258,8
1,55 126,5
1,60 127
HISTORICAL ALARM VISUALISATION:
The display will read:
FAULTS HISTORY
• By pressing the ENTER,key, the display will
read:
ERROR 01
•Pressing the ▼key, allows you to scroll
down the ten previous alarms saved in the
memory. After the tenth alarm, by pressing
the▼keyagainyoucangoontothenext
page.

Table of Contents