EAGLE ONE PRIMA | LIBRETTO ISTRUZIONI - USER HANDBOOK - MANUEL D’INSTRUCTIONS | 53
5.3
PRESSURE GAUGE /
PUMP ADJUSTMENT
To adjust the service pressure
of the boiler, thus regulating
the water temperature,
according to the various
requirements or features of
the coffee used, adjust the
pressure gauge from the
section TEMPERATURE of the
APP.
Recommended value: 1,8 - 2,2
bar (according to the type of
coffee).
To adjust the pump pressure,
use the setting knob
underneath the machine:
• INCREASE (clockwise).
• DECREASE
(counter-clockwise).
Recommended value: 9 bar.
GROUP
GROUP ADDRESS
DIP 1 DIP 2
1
5.4
PUSH-
BUTTON PANEL
REPLACEMENT
For correct functioning of the
machine, personalising the
button panel card at time of
replacement is necessary;
proceed as follows on the
selector placed on the card
(on the key side).
The keyboard name is
indicate on the selector side.
5.5
EASYCREAM WAND
ADJUSTMENT
(OPTIONAL)
Adjust the intensity of the
Easycream wand (optional)
by using the screw at the
top of the machine with a
screwdriver.