22
EN
MYTHOS
refers to the (›) symbol which permits the continuation of the programming, even of
other eventual dosages to be programmed that will continue flashing.
7.4.6 PrOGrAMMING OF THE SINGLE IMPULSE
Proceeding in the programming you enter the setting of the access time to the “single
impulse”.
What is the single impulse: immediately after having any dosage of coffee, the machine will
always place itself in the “single impulse” mode for a brief period of time (the
button will
flash), and then return to the “dose” mode. This is the time to set (from a minimum of 0 to
a maximum of 7 secs.) to allow the addition to the dose if the quantity ground is considered
insufficient.
With the
button you access the setting of the time of activation of the single impulse,
that is, for how long the single impulse should grind (from 0.2 to 0.5 sec.).
7.4.7 COUNT
Continuing in the programming mode with the key, it is possible to find out the count for
the number of coffees prepared for each single key, including each single pulse;
To return to the program mode re-push the lit button.
DOSES COUNT
DELAY 2 Sec
- Test + CONF
>
PULSE 0.3 Sec
- Test + CONF
>
1 COFFEE 1.70
- Test + CONF
>

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Victoria Arduino Mythos and is the answer not in the manual?

Victoria Arduino Mythos Specifications

General IconGeneral
Burr Size75 mm
ManufacturerVictoria Arduino
Frequency50/60 Hz
Grind AdjustmentStepless
Motor Speed1400 rpm
Voltage220-240 V
CategoryCoffee Grinder

Related product manuals