Settings
19
Changing the domestic hot water temperature Vitotronic 300-K, MW1S
In a multi-boiler system the Vitotronic 100, GC1 is without function.
The domestic hot water temperature is set on the Vitotronic 300-K, MW1S.
Desired DHW temp.
ºC
1. Open the hinged cover on the
programming unit.
12.
Press ; the previous
temperature setting flashes
in the display window.
13. / Press the / button
until the required
temperature value appears.
14. Confirm by pressing ;
the temperature value
stops flashing and is stored.
The display changes and
shows the boiler
temperature.
15. Close the hinged cover on the
programming unit.
Setting the energy saving mode for the holiday period Vitotronic 300-K, MW1S
If you want to set the heating system to the minimum energy consumption,
e.g. while you are away on holiday, choose the holiday program or the standby
mode (see ”Selecting the heating program” on page 7).
Holiday program
When the ”rw” heating program
is set (see page 7), central heating
takes place during the holiday
program with the selected ”reduced
room temperature” (see page 8), but
without domestic hot water heating.
The preset time program for central
heating and domestic hot water is
active on the dates of your departure
and return.
When the ”w” heating program is
set, only frost protection of the
heating system takes place during
the holiday program. Domestic hot
water takes place according to the
preset heating program on the dates
of your departure and return.
Please note:
The control unit is set up so that
the holiday program is effective
for all heating circuits.
If you require this to be changed,
please contact your heating
contractor.
5581 751 v1.1