3/N/PE 400 V/50 Hz
N1
N2N3L1L2L3
NL1L2L3
A
B
Fig. 51
A
Mains terminals, switching module, instantaneous
heating water heater
B
Jumpers
Do not remove jumpers
B
in the case of a 3/N/PE
400 V/50 Hz power supply.
■
Recommended power cable:
5 x 2.5 mm
2
■
Max. fuse rating 16 A
■
Economy tariff and power-OFF can be applied
Outdoor unit: Power supply
■
Economy tariff and power-OFF can be used
■
No parameters need to be set when using economy
tariff with power-OFF. The compressor is shut down
during the power-OFF time.
■
During power-OFF, the diagnostic functions for the
outdoor unit are not supported.
Note
Free terminals for internal use.
Outdoor unit power supply 230 V~
?
NL
?
B
L1 N
A
Fig. 52
A
Outdoor unit wiring chamber: See page 48.
B
Power supply 230 V/50 Hz
Installation sequence
Power supply (cont.)
6199585