VITODENS 200
Operating Instructions &
User’s Information Manual
Vitodens 200-W
WB2B Series
Wall-mounted, gas-fired condensing boiler
For natural gas and liquid propane
Heating input 31 to 370 MBH
8.5 to 105 kW
Read and save these in structions
for future reference.
IMPORTANT
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
WARNING
Improper installation, adjustment, and/or
operation could cause carbon monoxide
poisoning resulting in injury or loss of life.
This product must be installed and serviced by a
professional service technician who is
experienced and qualified in hot water boiler
installation and gas combustion.
WARNING
Do not store or use gasoline or other flammable
liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliances.
Do not touch any electrical switches, do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
Please file in Service Binder
5369 299 v1.0 b 08/2009
This trademark is registered with the U.S. Patent and Trademark Office.

Table of Contents

Other manuals for Viessmann Vitodens 200-W WB2B Series

Questions and Answers

  • R
    rgraySep 12, 2025
    How to troubleshoot communication fault with variable speed circulation pump on Viessmann Vitodens 200-W WB2B?
    • W
      wigginsteresaSep 12, 2025
      If your Viessmann Boiler displays error 'C5', indicating a communication fault with the variable speed circulation pump of the heating circuit connection set, check the setting of coding address ”30” and set it to “0” (30:”0”).
  • T
    Tyler WatkinsAug 25, 2025
    What to do if the fixed high limit switch is open on a Viessmann Boiler?
    • V
      Valerie ConwayAug 25, 2025
      If your Viessmann Boiler shows the error 'F2', which means the fixed high limit switch is open (activated), you should check the heating system fill level and the circulation pump. Bleed air from the system and inspect the fixed high limit switch and connecting cables. Finally, press the 'RESET' button.
  • J
    Joseph FloresAug 25, 2025
    What to do if the flame signal is missing on Viessmann Boiler at burner start?
    • J
      Jennifer HughesAug 26, 2025
      If the Viessmann Boiler displays error 'EE', indicating a missing or weak flame signal at burner start, you should check the ionization electrode and cable. Also, check the gas supply, condensate drain, ignition, and ignition module. Then, press the 'RESET' button.
  • S
    steve13Sep 23, 2025
    What does error F0 mean on Viessmann Vitodens 200-W WB2B?
    • T
      Tiffany DavisSep 23, 2025
      If your Viessmann Boiler displays error 'F0', indicating an internal fault, replace the control unit.
  • J
    James MaySep 12, 2025
    How do I fix a communication fault with the variable speed circulation pump in my Viessmann Vitodens 200-W WB2B?
    • R
      Robin FordSep 12, 2025
      If your Viessmann Boiler displays error 'C7', indicating a communication fault with the variable speed circulation pump of the heating circuit without a mixing valve, check the setting of coding address ”E5”.
  • P
    Paul TuckerSep 16, 2025
    What does error 9F mean on Viessmann Boiler?
    • E
      Elizabeth Williams DDSSep 16, 2025
      If your Viessmann Boiler displays error '9F', indicating a solar control unit fault, check the solar control unit.
  • B
    Bruce Jones DVMSep 5, 2025
    Why does the gas valve close too late on my Viessmann Boiler?
    • V
      valdezamandaSep 5, 2025
      If the Viessmann Boiler displays error 'F8', indicating the gas valve closes too late, check the gas valve and both control wiring/connections. Press RESET.
  • J
    Jose GarnerSep 5, 2025
    How to fix communication fault with the accessory kit on Viessmann Boiler?
    • Z
      zjordanSep 5, 2025
      If your Viessmann Boiler displays error 'bA', indicating a communication fault with the accessory kit for the heating circuit with mixing valve, check the accessory kit connections and coding. Turn on the accessory kit.
  • T
    Tonya WestSep 17, 2025
    What to do if the programming unit is faulty on Viessmann Boiler?
    • D
      Daniel HolmesSep 17, 2025
      If your Viessmann Boiler displays error 'A7', indicating a faulty programming unit, replace the programming unit.
  • B
    Brandon SextonAug 30, 2025
    What does error code Eb mean on a Viessmann Vitodens 200-W WB2B?
    • N
      Nathaniel ClayAug 30, 2025
      If your Viessmann Boiler displays error 'Eb', and the boiler control initiated a combustion calibration but could not complete the process, ensure the heat generated by the boiler is being removed. Check the connecting cable and the ionization electrode, and inspect the flue gas system for flue gas recirculation. Verify pump operation and check the switching points of the flow switch. Check the coding card, gas valve, and coding address 82. Also see address 12. Press ” RESET”.

Summary

Safety and Requirements

Safety, Installation and Warranty Requirements

Essential safety, installation, and warranty guidelines for the boiler.

Carbon Monoxide Safety

Risks and prevention measures for carbon monoxide exposure.

Fire Safety Precautions

Measures to prevent and respond to fire hazards associated with the boiler.

System Introduction and Controls

Getting Started and Boiler Overview

Initial steps, boiler model details, and factory presets for operation.

Control Panel and Indicators

Explanation of the control unit, buttons, displays, symbols, and heating circuits.

System Operation and Adjustments

Start-up and Shutdown Procedures

Instructions for starting, stopping, and standby operation of the heating system.

Adjusting Room Temperature

Setting permanent, reduced, temporary, and holiday room temperatures.

Selecting DHW Heating

Configuring domestic hot water heating settings and schedules.

Advanced Features and Monitoring

Further Adjustments

Customizing time, date, language, and display contrast settings.

Scanning System Information

Viewing temperatures, operating status, time programs, and fault codes.

Other Settings and Maintenance

Changing Heating Pattern and Troubleshooting

Addressing heating issues and adjusting boiler behavior based on symptoms.

Service and Maintenance Recommendations

Annual inspection and maintenance by qualified contractors for optimal performance.

Energy Saving Tips

Advice for efficient heating, water usage, and improving insulation.

Operating Instructions

Procedures for safe appliance lighting and general operating guidelines.

Viessmann Vitodens 200-W WB2B Series Specifications

General IconGeneral
TypeCondensing Boiler
Fuel TypeNatural Gas/LPG
Heat ExchangerStainless Steel Inox-Radial
InstallationWall-mounted
Max. Working Pressure3 bar
EfficiencyUp to 98%
Modulation RatioUp to 1:6
ControlVitotronic control system

Related product manuals