38
Vitotrol 300-E
Rated voltage
■
Plug-in power supply unit: 5 V
■
Power supply unit for flush mounting: 12 V
Rated current
■
Plug-in power supply unit: 0.8 A
■
Power supply unit for flush mounting: 0.33 A
Internet protocol IPv4
IP assignment DHCP
Power consumption 4 W
Protection class III
IP rating IP 20D to EN 60529, ensure through design/installation.
WiFi
WiFi frequency 2.4 GHz
WiFi encryption Unencrypted or WPA2
Frequency band 2400.0 to 2483.5 MHz
Max. transmitting power 0.1 W (e.i.r.p.)
Low Power Radio Status
Radio frequency 2.4 GHz
Encryption Encrypted
Wireless range through walls Up to 14 m (depending on wall thickness and wall type)
Permissible ambient temperature
■
Operation +5 to +40 °C
Installation in living spaces or boiler rooms (standard ambient con-
ditions)
■
Storage and transport –20 to +60 °C
Plug-in power supply unit
Rated voltage 100 to 240 V~
Rated frequency 50/60 Hz
Output voltage 5 V
Output current 2 A
Protection class II
Permissible ambient temperature
■
Operation 5 to +40 °C
Installation in living spaces or boiler rooms (standard ambient con-
ditions)
■
Storage and transport –20 to +60 °C
Specification
Specification
5839615
Appendix