16
6155063
Daily schedule:
A
B
F
For the central heating and the DHW cylinder, start
time C and end time D are dened in the daily
schedule so that selected operating status E is
maintained in the room (central heating program)
or DHW cylinder (DHW program). Between these
times, the energy saving temperature (energy saving
operating status) is active. The times during which
the DHW circulation pump runs constantly are set in
the time program for the DHW circulation pump. The
periods for maintaining selected operating status E
are set in the time program for the buffer cylinder.
To change the parameters for the daily schedule,
A Time program section
B Periods 1 to 5
C Starting time
D End time
E Operating status
F Command (active during editing):
Apply
Delete
Add
C D
E
select the time program and press the navigation
rotary switch. The rst parameter(start time) ashes.
Turn the navigation rotary switch left/right to set the
new period (hours and minutes separately) and press
it again to conrm. The next display starts to ash
so that the next parameter (end time) can be edited.
The last editable position is a command. To save the
changes, select the "Save" command and press
the rotary switch to complete editing. To delete the
selected switching time, select the corresponding
switching time for editing. Press the rotary switch to
call up the "Command" position, select "Delete"
and press the rotary switch again. To add a new
period, select the last dened period, press the rotary
switch to call up the "Command" position, select
"Add" and press the rotary switch again to add the
new period (the process for editing a new period is
described above).
Control panel VMN3 (cont.)
Settings