EasyManuals Logo

Viessmann Vitodens 100-W WB1C User Manual

Viessmann Vitodens 100-W WB1C
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Note on installation
for heating engineers
System boiler wiring instructions
for Vitodens 100-W, Typ WB1B & Typ WB1C
The Vitodens 100-W system boiler
offers several installation alterna-
tives.
From traditional 'Y' or 'S' plan
(2-pipe system) to weather compen-
sated 4-pipe system connected to an
un-vented DHW cylinder using the
integral expansion vessel and diverter
valve.
The advantages of connecting the
system boiler to a 4-pipe system are
as follows:
The DHW circuit operates indepen-
dently of the CH circuit
Dual temperature control, which
means the CH circuit can be
operated on weather compensated
system (reduced flow temperature)
Using the boilers temperature
cut-out device and integral diverter
valve to protect the cylinder from
overheating.
5414 394 8/2009/14

Other manuals for Viessmann Vitodens 100-W WB1C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Viessmann Vitodens 100-W WB1C and is the answer not in the manual?

Viessmann Vitodens 100-W WB1C Specifications

General IconGeneral
TypeWall-mounted gas condensing boiler
Energy Efficiency ClassA
Max. Heat Input35 kW
Heat Exchanger MaterialStainless steel
Control UnitVitotronic 100
Temperature Range30°C to 85°C
EfficiencyUp to 98%
Fuel TypeNatural gas
Dimensions400 x 700 x 360 mm
Water PressureMax 3 bar
ControlWeather-compensated control
Warranty2 years (extendable)

Related product manuals