Installation and Service
Instructions
VITODENS 100-W
5784 568 - 18 04/2020
for use by heating contractor
Vitodens 100-W B1HA/B1KA
Models 26 to 125
Wall-Mounted, gas-fired condensing boilers
On demand domestic hot water with Combi boiler
Read and save these instructions
for future reference.
IMPORTANT
Please file in Service Binder
Heating input: 21 to 125 MBH
6.2 to 36.6 kW
H

Table of Contents

Other manuals for Viessmann Vitodens 100-W B1HA 125

Question and Answer IconNeed help?

Do you have a question about the Viessmann Vitodens 100-W B1HA 125 and is the answer not in the manual?

Summary

Installation and Service Instructions

Vitodens 100-W B1 HA;B1 KA Models

Details installation and service for specific Vitodens boiler models.

Safety, Installation and Warranty Requirements

Key Requirements and Precautions

Covers product documentation, warranty, contractor needs, safety, and owner advice.

Dimensions and Clearances

Minimum Service and Combustible Clearances

Details required space around the boiler and clearance to combustible materials.

Boiler Dimensions and Connections

Boiler Dimensions and Connection Legends

Provides physical size measurements and explains symbols for boiler connections.

Piping Connections Overview

Illustrates and labels all piping connections for B1HA and B1KA models.

Boiler Connections

Vent Connections

Discusses proper routing and installation of the venting system for exhaust.

Gas Piping Requirements and Pressure Testing

Details codes, sizing, and leak testing procedures for gas supply piping.

Condensate and Siphon Management

Covers condensate drain connection and siphon filling for proper operation.

Safety Connections

Installing Safety Devices and Low Water Cut-Off

Instructions for installing pressure relief valve and low water cut-off requirements.

Installation Examples

Waterside Flow and Boiler Flow Rate Data

Provides charts for calculating waterside flow and lists maximum boiler flow rates.

B1 HA One Heating Circuit System Diagram

Illustrates a typical system setup for B1HA boilers with one heating circuit.

B1 KA One Heating Circuit System Diagram

Illustrates a typical system setup for B1KA boilers with one heating circuit.

Accessories

Start-up, Inspection and Maintenance

Setup Menu and System Filling Procedures

Overview of configurable settings and initial system filling steps.

Detailed System Filling and Bleeding Procedures

In-depth instructions for filling the heating system and removing air.

Checking the CO2 Content;Relay Tests

Procedures for measuring flue gas CO2 and performing relay tests for diagnostics.

Troubleshooting

Troubleshooting Steps and Room Temperature Adjustment

General approach to troubleshooting and adjusting room temperature settings.

Control Unit Faults Diagnostics Table

Lists fault codes, causes, and corrective measures for control unit errors.

Boiler Connection Checks (Troubleshooting)

Additional Information

B1 HA Wiring Diagram

Electrical wiring diagram illustrating connections for B1HA models.

B1 KA Wiring Diagram

Electrical wiring diagram illustrating connections for B1KA models.

Maintenance Record

Lighting and Operating Instructions

Safe Operation and Shut-Off Procedures

Critical safety warnings and step-by-step instructions for operating and shutting down the appliance.

Viessmann Vitodens 100-W B1HA 125 Specifications

General IconGeneral
ModelVitodens 100-W B1HA 125
CategoryBoiler
TypeWall-mounted condensing boiler
Fuel TypeNatural Gas
Heat Exchanger MaterialStainless Steel
Heating Capacity125 MBH
Efficiency95% AFUE
Max. Input (Natural Gas)35 kW
Max. Output (Natural Gas)125 MBH
Warranty10 years on heat exchanger