EasyManua.ls Logo

Viessmann VITODENS 100-W B1HE User Manual

Viessmann VITODENS 100-W B1HE
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Please file in Service Binder
6167 819 - 01 03/2021
Operating Instructions
VITODENS 100-W
Read and save these instructions
for future reference.
Product may not be exactly as shown
IMPORTANT
Do not store or use gasoline or other
ammable liquids in the vicinity of this
or any other boiler.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any boilers.
Do not touch any electrical switches,
do not use any phone in your building.
Immediately call your gas supplier
from a neighbor’s phone. Follow
the gas supplier’s instructions.
If you cannot reach your gas supplier,
call the re department.
Installation and service must be
performed by a quali ed installer,
service agency or the gas supplier.
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
WARNING
Improper installation, adjustment, and/
or operation could cause carbon monoxide
poisoning resulting in injury or loss of life.
This product must be installed and serviced
by a professional service technician who is
experienced and qualified in hot water boiler
installation and gas combustion.
WARNING
Vitodens 100-W
B1HE Series and B1KE Combi Series
Wall mounted gas-fired condensing boiler with 3.5 inch black/white display
On demand domestic Hot Water with Combi Boilers
For operation with natural gas or liquid propane gas
Heating Input: 8.5 to 199 MBH
2.5 to 58.3 kW
for the system user
H

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Viessmann VITODENS 100-W B1HE and is the answer not in the manual?

Viessmann VITODENS 100-W B1HE Specifications

General IconGeneral
ModelVITODENS 100-W B1HE
CategoryBoiler
Modulation Ratio1:10
Heat Exchanger MaterialStainless steel
Water PressureMax. 3 bar
TypeWall-mounted
EfficiencyUp to 98%
Fuel TypeNatural gas
Vent TypeRoom sealed
ControlVitotronic
DHW HeatingYes
Temperature Range30 to 80°C
Dimensions360 mm x 400 mm x 700 mm
NOx EmissionsClass 6 (20 mg/kWh)

Summary

Safety, Installation, and Warranty Requirements

Product Documentation and Contractor Requirements

Emphasizes documentation, licensed contractors, and warranty adherence for safe and proper installation.

Air Quality, Venting, and Carbon Monoxide Safety

Details hazards from contaminated air, improper venting, and carbon monoxide poisoning.

Owner's Safety Responsibilities

Outlines owner's duties regarding system operation, safety, and annual professional service.

General Information

Intended Use and Product Overview

Defines the boiler's purpose, features, and operating modes like weather-compensated and constant operation.

System Setup and Energy Saving Tips

Covers commissioning, preset configurations, and tips for energy efficiency and comfort.

Operation Principles and Controls

Display and Button Operations

Explains the control unit, display, buttons, and system overview for user interaction.

System Overview and Menu Navigation

Details how to navigate system overviews and access the main menu for adjustments.

Time Programs for DHW Heating

Setting Up Time Programs

Guides users on how to input and configure time programs for central heating and DHW based on time phases.

DHW Heating Control

DHW Temperature Adjustment and Programs

Explains how to set and adjust the domestic hot water temperature, with safety warnings about scalding.

Manual DHW Heating Control

Details how to initiate a single instance of DHW heating outside the programmed schedule.

DHW Hygiene and Scald Protection

Enhanced DHW Hygiene Program

Explains how to activate a hygiene program to heat water to higher temperatures weekly or daily.

DHW Scald Protection Settings

Describes how to enable or disable scald protection for DHW to prevent burns.

Further Adjustments and System Settings

Display Brightness and Lightguide Control

Guides users on adjusting screen brightness and enabling/disabling the control unit's status light.

Time, Date, Language, and Units

Covers setting the system's time, date, and preferred language for operation.

Internet Connectivity and Energy Metering

Establishing WiFi Connection

Instructions for establishing an internet connection via WiFi for remote system control.

Energy Metering and Factory Settings

Covers setting energy metering values and restoring the system to its original factory default settings.

Accessing System Information

Help Messages and System Data

How to retrieve help messages and view current system data like temperatures and group information.

Licences and Energy Metering Details

Accessing energy consumption data and software licence information for the unit and wireless module.

Message and Fault Management

Checking and Acknowledging Faults

Procedures for checking and noting other system faults, contacting the contractor, and navigating error messages.

Service and Message History

How to view a history of all past system messages, including faults, warnings, and information.

Service and Diagnostic Functions

Emissions Test Mode

Instructions for activating the emissions test mode, intended for licensed contractors during annual inspections.

Safety Cut-Out Test Procedure

Procedure for testing the high limit safety cut-out function of the boiler system.

Boiler Switching and System Pressure

Boiler Shutdown and Startup

Detailed steps for powering on the boiler, checking system pressure, and ensuring readiness for operation.

Troubleshooting Common Issues

Room Temperature Problems

Identifies reasons for cold rooms, such as boiler shutoff or incorrect settings, and provides solutions.

Hot Water Supply Issues

Lists potential causes for lack of hot water, from boiler switch-off to fuel supply issues, and their fixes.

Maintenance and Cleaning Procedures

Boiler and DHW Tank Maintenance

Guidelines for cleaning the boiler surface and internal components of the DHW tank, recommending professional service.

Safety Valve and Filter Checks

Details regular inspection requirements for the boiler, DHW tank, safety valves, and water filters for optimal performance and safety.

Appendix - System Overviews

Main Menu Overview - Heating

Lists available information and settings within the main menu related to heating, including temperatures and operating programs.

Main Menu Overview - DHW and Network

Details main menu options for DHW settings, time programs, and network status.

Appendix - Terminology and Curves

Glossary of Operating Terms

Defines terms like Standby mode, Operating program, Operating status, and different heating operations.

Heating Curve Explanation

Explains heating curves, slope, and shift settings to illustrate the relationship between outside temperature and supply temperature.

Operating Instructions and Safety

Pre-Operation Safety Checks

Crucial safety steps before operating the boiler, including gas leak checks and emergency procedures.

Boiler Startup and Shutdown

Step-by-step instructions for starting up and safely turning off the boiler, including gas control.

Related product manuals