EasyManua.ls Logo

Viessmann Vitodens 100-W WB1B User Manual

Viessmann Vitodens 100-W WB1B
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
VIESMANN
Installation and service
instructions
for contractors
Vitodens 100-W
Type WB1B, 9.0 to 35.0 kW
Wall mounted gas fired condensing boiler
Natural gas and LPG version
VITODENS 100-W
5354 802 GB 2/2008 Please keep safe.

Other manuals for Viessmann Vitodens 100-W WB1B

Question and Answer IconNeed help?

Do you have a question about the Viessmann Vitodens 100-W WB1B and is the answer not in the manual?

Viessmann Vitodens 100-W WB1B Specifications

General IconGeneral
TypeWall-mounted gas condensing boiler
Modulation range1:4
EfficiencyUp to 98% (Hs)/109% (Hi)
Energy efficiency classA
Flue gas connection60/100 mm
Max. Heat Input35 kW
Control UnitVitotronic 100
Fuel TypeNatural Gas / LPG

Summary

Installation and Service Instructions

Vitodens 100-W Overview

Type WB1B, 9.0 to 35.0 kW wall mounted gas fired condensing boiler, natural gas and LPG version.

Safety Instructions

Safety Symbols and Target Group

Explanation of danger symbols, notes, and target group for qualified personnel.

Regulations and Standards

Legal instructions regarding accident prevention, environmental protection, and applicable safety regulations.

Gas Leak Safety Procedures

Danger and measures to take if gas is detected, including evacuation and shutting off supply.

Flue Gas Safety Procedures

Danger and measures to take if flue gas is detected, including ventilation and shutting off the system.

Working on the System Safely

Procedures for safely working on the gas and electrical systems, including isolation.

Component Repair and Spare Parts

Guidelines for replacing components and using genuine Viessmann spare parts.

Ancillary Components and Warranty

Caution regarding untested parts and unauthorized modifications affecting safety and warranty.

Preparing for Installation

Product Information

Details about the Vitodens 100-W, WB1B, set up for natural gas operation.

Boiler Installation Preparation

Instructions for preparing the boiler installation, including dimensions and connections.

Dimensions and Connections Overview

Table detailing rated output range and corresponding dimensions (a) in mm.

Fitting the Wall Retainer

Step-by-step guide for fitting the wall retainer using an installation template.

Preparing Water, Gas, and Electrical Connections

Steps for preparing water, gas, and electrical connections, including IEEE standards.

Installation Sequence

Mounting the Boiler

Procedure for removing the front panel and mounting the boiler onto the wall retainer.

Water Side Connection Details

Reference to separate instructions for fittings on the heating water and DHW sides.

Safety Valve and Gas Connection

Instructions for connecting the safety valve drain and gas supply, including leak tests.

Condensate Drain and Siphon

Connecting the condensate drain and filling the siphon with water.

Balanced Flue and Control Unit Opening

Connecting the balanced flue and opening the control unit.

Electrical Connections and Sensor Installation

Overview of electrical connections, accessory connections, and outside temperature sensor installation.

Control Unit Cable Routing

Steps for routing connecting cables and closing the control unit, noting cable temperature limits.

Commissioning, Inspection, and Maintenance

Commissioning and Maintenance Steps

List of commissioning, inspection, and maintenance steps with corresponding page numbers.

Heating System Filling Procedure

Detailed instructions for filling the heating system, including water quality requirements.

Boiler Venting and Pump Adjustment

Procedure for venting the boiler and adjusting the circulation pump.

CO2 Content Check and Adjustment

Procedure for checking and adjusting the CO2 content for upper and lower outputs.

Burner Removal and Gasket Check

Steps for burner removal and checking the burner gasket and gauze assembly.

Electrode Maintenance

Steps for checking and adjusting electrodes.

Heat Exchanger Cleaning

Procedure for cleaning the heat exchanger.

Condensate Drain and Siphon Cleaning

Steps for checking the condensate drain and cleaning the siphon.

Burner Installation

Procedure for installing the burner, including torque settings and connections.

Gas Tightness and Front Panel Fitting

Checking gas equipment tightness and fitting the front panel.

System User Instruction

Requirement for the system installer to hand over operating instructions and instruct the user.

Troubleshooting

Function Sequence and Faults

Flowchart illustrating the boiler's function sequence and potential faults with corresponding measures.

Display Fault Messages

Table listing fault codes, causes, and recommended measures for various error conditions.

Resetting the Control Unit

Instructions on how to reset the control unit by turning the rotary selector to 'RESET'.

Repairs

Front Panel and Sensor Access

Steps for removing the front panel and accessing the outside temperature sensor.

Sensor Checks and Replacements

Procedures for checking and replacing outside, boiler water, cylinder, and outlet temperature sensors.

Temperature Limiter and Flue Gas Sensor Check

Procedure to check the temperature limiter and flue gas temperature sensor.

Flow Limiter and Heat Exchanger Repair

Steps for replacing the flow limiter and checking/repairing the plate-type heat exchanger.

Fuse Check

Procedure for checking fuse F4 after opening the control unit casing.

Gas Type Conversion

Converting from LPG to Natural Gas

Steps to remove the gas restrictor and fit the gas train with new gaskets.

Control Unit Gas Type Adjustment

Adjusting the control unit for natural gas or LPG operation and saving the setting.

Burner Adjustment Reference

Reference to 'Checking the CO2 content' on page 22 for burner adjustment.

Control Unit Functions

Weather-Compensated Mode Operation

Explanation of weather-compensated mode and heating curves based on outside temperature.

Connection Diagrams

Wiring Diagram Overview

Schematic diagram illustrating the electrical connections and components of the boiler.

Wiring Diagram Component Legend

Legend and list of components referenced in the connection and wiring diagram.

Parts Lists

Spare Parts Identification

List of spare parts with item numbers and descriptions for ordering.

Exploded Views of Components

Diagrams showing burner, heat exchanger, hydraulic, and control unit components.

Technical Specifications

Boiler and Combi Boiler Specifications

Technical specifications for gas fired condensing boiler and combi boiler models.

Certificates

Declaration of Conformity

Statement of conformity with standards and directives for the Vitodens 100-W.

Related product manuals