Settings:
Control panel VMN3 (cont.)
Settings
A Period number (max. 5)
B Start time of the selected program
C End time of the selected program
D Temperature selection: , , ,
If other heating circuits are installed in the system,
these must be selected in the menu:
■
Boilers
■
Heating circuits.
If no other heating circuits are installed, the list of
settings appears with a boiler.
Boiler settings
■
Central heating ow temperature: Set ow
temperature (only available in the basic module with
xed parameters for the room temperature control
unit)
[Conguration > CH > Control > Fixed parameters].
■
Room temperature (only available when Tr sensor
is active) [Conguration > Room temp. > Room
sensor > Tr]:
– Energy saving
, Comfort- , Comfort ,
Comfort+ : Set room temperature available in
the schedules
– Party, Holiday: Selection of temperatures to be
applied in the PARTY and HOLIDAY programs.
■
DHW temperature|
(only available in systems with a cylinder):
– Energy saving
, Comfort : Selection of
DHW temperature available in the schedules.
■
Central heating program (only available in the basic modules and with an active
Tr sensor) [Conguration > Room temperature > Room temperature sensor > Tr]
– Numbers 1 to 8 > Setting of 8 daily programs
in each day program. There are 5 adjustable
periods, each of which can be assigned a
room temperature ( , , , ).
The process for setting daily programs is
described in Daily schedule.
Note:Ifnointervalsaredened,an
energy saving temperature is used. ( ).
– Weekly: A preset is assigned on each day of the
weekly program.