Page 6 ;&(%$*4.8"4,7%<'*#$"&8#=%/7*,#*%4,77%>?@@@?@AA?BCDC1 Item 63299
EF;6GH IJ6KFGLIM NFLMG6MFMO6E6GPJ
E/*4"2"4,$"&8#
Electrical Rating 120 VAC / 60 Hz / 3.5 A
Charge Settings* 2 A / 8 A / 15 A
Battery Cables
6', 14 AWG
Red = Positive
Black = Negative
Power Cord 6'
ZF5/*(,3*%"#%&87Y%/(*#*8$%)."7*%4&88*4$*9%$&%,%+,$$*(Y1
E*$'/
%K*,9%$.*%6MGLK6%LNJIKGFMG%EF;6GH%LM;IKNFGLIM%#*4$"&8%,$%$.*%+*3"88"83%&2%$."#%
5,8',7%"847'9"83%,77%$*X$%'89*(%#'+.*,9"83#%$.*(*"8%+*2&(*%#*$%'/%&(%'#*%&2%$."#%/(&9'4$1
O&8$(&7#
F5/*(,3*%
S'$$&8
O.,(3*%S'$$&8
TOU%
U"#/7,Y
S,$$*(Y%GY/*%
S'$$&8
K*4&89"$"&8%
S'$$&8
Q"8$*(%N&9*%
S'$$&8
TOU%U"#/7,Y- Displays charging status, charging
current, voltage, battery type, recondition
mode, winter mode, and error codes.
F5/*(,3*%S'$$&8- Use to set the amperage output
from 2 A, 8 A, 15 A and automatic charging rate.
S,$$*(Y%GY/*%S'$$&8- Use to select the
battery type from standard or AGM. For
GEL batteries use the standard setting.
O.,(3*%S'$$&8- Use to begin charging manually.
K*4&89"$"&8%S'$$&8- Use to activate the
battery reconditioning function for weak,
sulfated, or deeply discharged batteries.
Q"8$*(%N&9*%S'$$&8- Use to activate the
winter charging mode in cold weather.
J(&$*4$"&8%;*,$'(*#-
Overheating protection – If the Charger overheats,
it will automatically shut off. Charger will
automatically resume when it has cooled down.
Reverse polarity – if the cables are connected
incorrectly, the Charger will not function, and LCD
screen displays reverse polarity error code.
Overcharging protection – if the battery
cannot be fully charged within 24 hours,
Charger will stop charging automatically.