BBAASSIICC SSPPEECCIIFFIICCAATTIIOONNSS
IINNTTEERRIIOORR AANNDD EEXXTTEERRIIOORR PPOOWWEERR HHOOOODDSS
RREECCOOMM.. NNUUMMBBEERR OOFF 112200VVAACC//6600HHzz
DDEESSCCRRIIPPTTIIOONN CCFFMM
11
HHAALLOOGGEENN FFIILLTTEERRSS SSPPAACCEERRSS MMAAXX.. AAMMPPSS
33
((iinntt..--iinntteerriioorr;; eexxtt--eexxtteerriioorr
LLIIGGHHTTSS
((IInntteerriioorr//EExxtteerriioorr))
1188”” HH.. WWaallll
30”W.* 300 int/600 int./1200 int./900 ext./1200 ext. 2 2 0 2.4/4.6/6.6/6.6/3.9
36”W.*
300 int/600 int./1200 int./900 ext./1200 ext. 2 2 1 2.4/4.6/6.6/6.6/3.9
42”W.* 600 int./1200 int./900 ext./1200 ext. 2 3 0 4.6/6.6/6.6/4.0
48”W.
1200 int./1200 ext./1500 ext. 3 3 0 7.0/4.3/5.1
AAPPPPRROOXXIIMMAATTEE RREECCOOMMMMEENNDDEEDD MMAAXX.. DDUUCCTT
MMOODDEELL NNUUMMBBEERR CCFFMM
11
DDUUCCTT SSIIZZEE RRUUNN
22
((fftt..))
FFoorr UUssee wwiitthh hhooooddss::
VIV300 (interior) 300 7” round 50
VIV600 (interior) 600 7” round 50
VIV1200 (interior) 1200 10” round 50
VEV900 (exterior) 900 10” round 50
VEV1200 (exterior) 1200 10” round 50
VEV1500 (exterior) 1500 10” round 75
PPRROOPPEERR IINNSSTTAALLLLAATTIIOONN//DDUUCCTTIINNGG IISS EEXXTTRREEMMEELLYY IIMMPPOORRTTAANNTT TTOO EENNSSUURREE MMAAXXIIMMUUMM PPEERRFFOORRMMAANNCCEE FFRROOMM AANNYY
VVEENNTTIILLAATTIIOONN PPRROODDUUCCTT
1. •All CFMs stated are based on tests at .1 static pressure: without applying static pressure, CFM would be greatly
overstated.
2. •Duct run length is for general reference only; for longer duct runs, increase duct size and contact a qualified and trained
installer.
•Straight runs and gradual turns are best; for example, each 90
o
elbow is equivalent to 5-10 feet (1.52 - 3.05 cm) of
straight run.
•Never use flexible duct; it creates back pressure/air turbulence and greatly reduces performance.
•Proper performance is dependent upon proper ducting; make sure that a qualified and trained installer is used.
••CChheecckk wwiitthh aa qquuaalliiffiieedd aanndd ttrraaiinneedd iinnssttaalllleerr oorr llooccaall ccooddeess ffoorr mmaakkeeuupp aaiirr rreeqquuiirreemmeenntt,, iiff aannyy..
3. •Max. amp rating for hoods includes recommended ventilator kit rating; all products must be hard wired direct with 2-
wire with ground.
**11220000 CCFFMM ((oorr 11550000 CCFFMM iiff aapppplliiccaabbllee)) eexxtteerriioorr vveennttiillaattoorr sshhoouulldd bbee uusseedd wwhheenn iinnssttaalllleedd oovveerr
rraannggeess/
/rraannggeettooppss wwiitthh ggaass ggrriillll..
3