WALL AND ISLAND HOODS
Basic specifications – Ventilation products
Number of
Lights
76 cm W. EVWH3048
91 cm W. EVWH3648
122 cm W. EVWH4848
Ventilators*
Number of
Filters
Model
Number of
Heat Lamps
Exterior-PowerInterior-Power
46 CM HIGH WALL HOOD CANOPIES – 61 CM DEEP
46 CM HIGH ISLAND HOOD CANOPIES – 76 CM DEEP
2
2
3
2
2
2
1.450 m
3
/h
1.450 m
3
/h**
1.700 m
3
/h
2 x 720 m
3
/h
2 x 720 m
3
/h**
2 x 720 m
3
/h**
2/1
2/1
2/1,5
2
2
3
91 cm W. EVIH3608
106 cm W. EVIH4208
137 cm W. EVIH5408
4
4
6
N/A
N/A
N/A
1.450 m
3
/h**
1.700 m
3
/h
1.700 m
3
/h
2 x 720 m
3
/h**
2 x 720 m
3
/h**
2 x 720 m
3
/h**
2/1
2/1,5
2/1,5
4
4
6
*An interior-power or exterior-power ventilator kit must be purchased for installation with all 46 cm high hoods.
**A 1.700 m
3
/h exterior ventilator should be used when installed over range/rangetop with gas char-grill.
*** Maximum amp rating for hoods includes recommended ventilator kit rating; all products must be hard wired with 2-wire with ground.
Interior Ventilators
Approximate m
3
/h*
Recommended duct size
Maximum duct run**
220VAC/50Hz MAX. AMPS
Exterior Ventilators
Model
46 CM HIGH WALL AND ISLAND HOODS
Integrated with hood
2 x 720 m
3
/h
20,0-25,0 cm
15,2 m
2
10
1.450 m
3
/h
20,0-25,0 cm
15,2 m
1
15
1.700 m
3
/h
20,0-25,0 cm
15,2 m
1,5
Ventilator kits
Proper installation is extremely important to ensure maximum performance from any ventilation product.
* All m
3
/h stated based on tests with 0,1 static presssure: without applying static pressure (some brands consciously do not), m
3
/h could be
greatly overstated.
** Duct run length is for general reference only; for longer duct runs, increase duct size and contact a qualified and trained installer.
• Straight runs and gradual turns are best; for example, each 90-degree elbow is equal to 1,52-3,05 m of straight run.
• Use flexible duct; creates back pressure/air turbulence and greatly reduces performance.
• Proper performance is dependent upon proper ducting; make sure that a qualified and trained installer is used.
• Check with a qualified and trained installer or local codes for makeup air requirements, if any.
230VAC/50HZ
Max Amps***
Interior/Exterior