A. Entering the Programming Mode
1. Local
2. Remote
Programming
B. Factory Default Settings
Step 1. Move the PROG/NORM switch to PROG and plug an analog phone into the TELCO jack.
Step 2. After taking the phone off hook, wait for two beeps.
Step 3. Program as shown in sections B-T.
Step 4. To exit programming, hang-up. Set the PROG/NORM switch to NORM.
Step 1.
Make sure the PROG/NORM switch is set to the NORM position and that there is a CO line or
analog PABX/KSU extension in the TELCO jack.
Step 2.
Call into the K-2000-DVA on that line or extension. The unit will answer after the set ring delay
(see Programming section G) and a single beep should be heard.
Step 3.
Enter a Q and the six-digit security code (factory default is 845464). If the correct code is entered,
two beeps should be heard.
Note: The security code must be entered within 20 seconds otherwise the K-2000-DVA will time
out and hang up. When in programming, if 20 seconds elapse without Touch Tones being
entered or a message being recorded, the K-2000-DVA will automatically exit programming and
hang up.
Step 4. Program as shown in sections B-T.
Step 5.
To exit programming, hang-up. After the 20 second timeout has elapsed, the K-2000-DVA will
be ready for normal operation. Alternatively, dial ##7 and the K-2000-DVA will immediately be
ready for normal operation
Note: Correct programming entries are implemented and then acknowledged by two beeps. Incorrect
programming entries are discarded and receive three beeps to indicate an error.
Security Code 845464 (V-I-K-I-N-G) (see section D
Access Code 123456 (see section F)
Alarm Dialer Mode Enabled (see section E)
Store Caster Mode Disabled (see section E)
Phone Numbers Not Programmed (see section O)
Messages Not Recorded (see section R)
Ring Delay 1 (see section G)
Ringback Limit 6 (see section H)
Pager Number Not Programmed (see section P)
Call Progress Detection Enabled (see section J)
Dialing Speed Normal (see section I)
Alarm Input Configuration N/O (Enabled) Momentary (see section K)
Lap Counter 1 (see section L)
Message Repeat Counter 2 (see section L)
Qualifier Timer 0 - disabled (see section M)
Resume Timer 0 - disabled (see section N)
Hookswitch Flash Before Dialing Disabled (see section Q)