Troubleshooting
©2012 Viking Preferred Service 9
Control Board Test Points
Component Testing
Component
Operating Voltage
(Approximate)
*Resistance (Approximate) Test Location
Control Board
(Input Voltage)
240 VAC n/a K17 red - P12 black (L1)
Convection Element 240 VAC 18.2 W K17 yellow - P2 white/red
Outer Broil Element 240 VAC 40.2 W K17 yellow - P6 grey
Inner Broil Element 240 VAC 22.8 W K17 yellow - P6 violet
Outer Bake Element 240 VAC 37.7 W K17 yellow - P5 blue
Inner Bake Element 240 VAC 38.6 W K17 yellow - P5 orange
RTD (Resistive
Thermal Device)
- 1100 W at 75°F (See chart for more
options)
P14 violet - grey
Convection Motor 240 VAC 112 W K17 red - P4 blue/black (FWD)
K17 red - P4 yellow (REV)
Blower Motor 120 VAC 18.8 W P1 white - P11 white/black
Door Latch Motor 240 VAC 12.86 kW K17 red - P12 black/white
Door Latch Switch
(Door Unlocked)
7.86 VDC ∞ (Open) P15 brown - orange
(**disconnected from board)
0 VDC 0 W (Closed) P15 brown - blue/white
Door Latch Switch
(Door Locked)
0 VDC 0 W (Closed) P15 brown - orange
(**disconnected from board)
7.70 VDC ∞ (Open) P15 brown - blue/white
(**disconnected from board)
Cycle Light 7.45 VDC ∞ (Open-30 meg W) P1 violet - orange/black
Clean Light 7.45 VDC ∞ (Open-30 meg W) P1 violet - white/black
Oven Light Switch -
OFF (Door Closed)
7.76 VDC ∞ (Open) P15 brown - violet/white
(**disconnected from board)
Oven Light Switch -
ON (Door Closed)
0 VDC 0 W P15 brown - violet/white
(**disconnected from board)
Oven Door Switch
(Door Open)
11.0 VDC ∞ (Open) P15 brown - grey
(**disconnected from board)
Oven Door Switch
(Door Closed)
0 VDC 0 W P15 brown - grey
* Resistance checks made with power off.
** Disconnect connector from board for resistance test only.