Safety
4 Safety
4.1 Intended use
The ProDetect 2 must be used exclusively with fresh water. Dirt particles in the water can block the solenoid valve
and the sieve seal. The maximum permissible line pressure must not exceed 4 bar.
Use the ProDetect 2 only in combination with the following urinals:
•
Architectura 5586 / 5587 / 5574
•
Subway 7513
•
O.novo / Omnia 7507 / 7557 / 7527
•
Venticello 5504
Intended use also includes:
•
observance of all instructions in these operating instructions
•
compliance with all instructions in the installation instructions
•
compliance with the inspection and maintenance tasks
•
exclusive use of original parts
4.2 Reasonably predictable misuse
Any use other than those listed under "intended use", or use which goes beyond this, is considered to be non-
intended.
For damage arising from non-intended use, the operator himself is exclusively responsible, and the manufacturer
does not accept any liability whatsoever.
Care must be taken when installing the ProDetect 2 because of the limited assembly space of urinals.
Note the following instructions:
•
Do not crush cables
•
The sensor must be installed in the correct position and in the correct sensor direction
•
The power supply for the mains model must be installed in the correct position
•
Use only recessed sockets for installation of the mains power connection
•
Do not use surface-mounted sockets with projecting surrounds when installing the mains power connection
•
Once the urinals have been installed, no cables may hang down through the inspection shaft
Important
Before opening the connected water line, you must ensure that the urinal control system
has previously been commissioned for a minimum of 30 seconds (power connection). This
applies to the battery and mains versions.
S. 42