Installation
7 Installation
Important
Before opening the connected water line, you must ensure that the urinal control system
has previously been commissioned for a minimum of 30 seconds (power connection). This
applies to the battery and mains versions.
7.1 Suitable urinals
Important
Urinals with vertical discharge
Always use a mains model for urinals with vertical discharge.
We recommend installing the optional Bluetooth adapter. This will ensure simple operation
of the system without dismantling the urinal.
Use the ProDetect 2 only in combination with the following urinals:
•
Architectura 5586 / 5587 / 5574
•
Subway 7513
•
O.novo / Omnia 7507 / 7557 / 7527
•
Venticello 5504
7.2 Installing the hosing
Important
At first installation of urinal and ProDetect 2
•
Carry out all necessary steps in the separate assembly instructions for fitting the urinal
before installing the hosing.
•
Flush the water line before installation to remove any contamination.
•
Before installing the hosing, make sure that the seals on the solenoid valve are arranged
correctly (see sketch).
Important
Retrospective installation of ProDetect 2
•
Before installing the hosing, remove the urinal attachments.
•
Flush the water line before installation to remove any contamination.
•
Before installing the hosing, make sure that the seals on the solenoid valve are arranged
correctly (see sketch).