21
EN
4. CONFIGURATION VIA MENU
The display provides the ability to congure the basic parameters of the panel.
There are two menus:
1. administrator: the administrator side lets you modify the display module interface;
2. installer: lets you change some of the functional parameters of the panel.
You access the menu by simultaneously pressing
(UP) + (DOWN) for 5 s and entering the respective pass-
words.
The passwords have a xed length and are composed of a sequence of the “
(UP)” “ (DOWN)” “ (OK)”
buttons.
The default passwords are:
Administrator:
(UP) + (UP) + (UP) + (UP) + (UP)
Installer: (DOWN) + (DOWN) + (DOWN) + (DOWN) + (DOWN)
The passwords can be changed via SaveProg.
4.1. Administrator menu
The structure is summarized below:
Label Settings
Level 0 Level 1 Level 2
Display
Language
Italian, English, French, German, Spanish, Greek, Por-
tuguese, Russian, Swedish, Dutch and Polish (Default:
Italian)
Menu Navigation Navigable/Direct (Default: Navigable)
Font Normal/Large (Default: Normal)
LCD
Brightness 1-5 (Default:5)
Colours B/W, BLUE, GREEN (Default: B/W)
Standby ON/OFF (Default: ON)
The items are accompanied by the current value of the set parameter.
4.1.1. Language
This lets you choose the language of the messages of the user and installer menus.
• Language: Italian, English, French, German, Spanish, Greek, Portuguese, Russian, Swedish, Dutch and Polish
4.1.2. Menu
This lets you choose the variant of the menu structure according to need.
• Navigation: Navigable/Direct
Navigable: lets you scroll through the menu selecting the items with the arrows and entering the selected
sections with
(OK);
Direct: lets you enter the items directly by pressing the
(UP)/ (DOWN) control buttons of the display
module