2 Station Conguration
2.1 Logging into the Turbine Station
The Turbine Station features an embedded web interface
which allows users to log in via a standard web browser.
To do this, your PC and the Turbine IP station have to be
connected together via a PoE switch using network cables:
1. Connect the PC to the PoE switch
2. Connect the PoE port on the station to the PoE switch
When the Turbine Station is connected to the network, the IP
address of the station is automatically obtained in one of two
ways:
1. IP address obtained from a DHCP server
2. If there is no DHCP server, an IP address in the range
169.254.x.x will be assigned.
To make the station speak its IP address:
Press the call button on the station
- when the station is not yet registered
Access the station by logging into the web interface using a
standard web browser:
1. Open a web browser
2. In the browser’s address bar, type the station IP address
and press the ENTER key
- The station login page will be displayed.
To log into the station:
1. Click Login
2. Enter the default User name: admin
3. Enter the default password: alphaadmin
2.2 Station Main Settings
Click Station Main > Main Settings to access the page
for conguring station mode and IP parameters.
PoE Network Switch
Turbine IP Station
Directory Number: 12
Name: Rear Entrance
IP Address: 169.254.1.103
or DHCP
Turbine IP
or DHCP
Station
Directory Number: 11
Name: Main Entrance
IP Address: 169.254.1.102
Turbine IP Station - Pulse Server
Directory Number: 10
Name: Reception Desk
IP Address: 169.254.1.99
Station Mode
Select the Use Pulse or Use Pulse Server radio-button
L Use Pulse Server must be selected to be able to carry out the
congurations described in the following sections.
Turbine Frontboard
Depending on the type of Turbine Compact station, select
one of the options from the drop-down box:
- Kit
- Normal (TCIS-1, TCIS-2, TCIS-3)
- OLED Labels (TCIS-4, TCIS-5)
- Scrolling Station (TCIS-6)
IP Settings
DHCP – Select this option if the IP station shall receive
IP Settings from a DHCP server.
Static IP – Select this option if the IP station shall use a
static IP address. Enter values for:
- IP-address
- Subnet-mask
- Gateway
- DNS Server 1 (optional - for network administration)
- DNS Server 2 (optional - for network administration)
- Hostname (optional - for network administration)
Read IP Address
Check the Read IP Address box to enable an
unregistered station to speak the IP address when the
call button is pressed.
Click Save followed by Apply to apply the new
conguration settings.
2.3 Connect other Intercom Stations
Connect all other IP intercom stations to the network. Note
that all other IP intercom stations have to be on the same
LAN (IP subnet) as the Pulse Server.
Wait for the stations to boot up (approximately 60 seconds)
before proceeding to the next step.
2.4 Congure Directory (Phonebook)
Log into the Pulse Server station with the new IP address
(e.g. 169.254.1.99) that you have just set under Station
Main > Main Settings. After login, you will nd a new Server
Management tab
Under the Server Management tab, select Server
Conguration > Directory Settings
The Pulse Server station will auto-discover all the other
stations on the LAN.
To identify the individual stations on the LAN:
Click Play
- You should now hear a tone from the station you selected.
You can now set directory numbers, names, IP addresses,
proles, etc. for all the stations in the network. In our
example, the Pulse Server station is designated as Reception
Desk with directory number 10 while the two substations are
the Main Entrance and Rear Entrance with directory numbers
11 and 12 respectively.

Other manuals for Vingtor Stentofon TCIS-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vingtor Stentofon TCIS-2 and is the answer not in the manual?

Vingtor Stentofon TCIS-2 Specifications

General IconGeneral
BrandVingtor Stentofon
ModelTCIS-2
CategoryIntercom System
LanguageEnglish

Related product manuals