Information to avoid personal injury, damage to the instrument, malfunctions or incorrect results.
Explains warning terms and symbols used in the manual for clear understanding and safe operation.
Lists other documents providing additional safety information for working with the measuring system.
Specifies that the instrument is designed exclusively for electrochemical measurements in laboratory and field.
Outlines essential requirements for safe operation, including using the correct power supply and environmental conditions.
Defines conditions under which the instrument must not be put into operation, such as visible damage or improper storage.
Provides guidance on cleaning the instrument case and handling sensitive materials to prevent damage.
Clarifies the owner's responsibility for user safety and informing users about safe operation and potential risks.
Lists the parameters measured by the different models: pH, mV, ORP, Cond, TDS, Temp.
Presents detailed technical specifications for measuring ranges, resolution, calibration, and system parameters.
Details the components and information displayed on the instrument's screen, including measurement parameters and status indicators.
Explains the function of each button on the instrument's keypad for navigation and operation.
Describes the meaning of the two-colour LED (red and green) for providing information on the system status.
Lists the standard components included with the instrument, such as cables, probes, and accessories.
States that the device is ready for end-user use upon leaving the factory and that batteries are included.
Provides instructions on how to turn the instrument on and off using the power button.
Step-by-step guide for replacing the 3 AA 1.5V batteries, including safety precautions.
Advises using the original transport case for moving the instrument, which is shaped to house the instrument and sensor.
Details the functions of each button (Power, Esc/Cal, Mode, VOK/Setup) for device operation and navigation.
Explains how to connect probes and accessories to the BNC and RCA connectors, advising the use of original parts.
Describes the meaning of various symbols and icons displayed on the screen, such as error indicators and battery level.
Explains how to enter and navigate the SETUP menu to modify parameters and settings.
Details the setup menu structure for pH, ORP, Cond, TDS settings and general instrument settings.
Guide on how to access and navigate the pH parameter setup menu for configuration.
Details the setup menu structure for the pH parameter, including program options and factory default settings.
Resets pH menu parameters to default settings without erasing stored data.
Allows offset adjustment for temperature reading if a difference between measured and real values is detected.
Detailed step-by-step guide for performing automatic pH calibration using buffer solutions.
Provides instructions for manual pH calibration, including selecting custom values and adjusting measurements.
Guide on how to perform pH measurements, including connecting the electrode and interpreting stability indicators.
Explains the functionality of DHS electrodes, including saving calibration data and automatic recognition.
Lists calibration errors for pH, including 'NOT STABLE', 'WRONG BUFFER', 'SLOPE OUT OF RANGE'.
Guide on accessing and navigating the ORP parameter setup menu for configuration.
Instructions for performing automatic ORP calibration with a standard 475 mV solution.
Explains the principles of conductivity measurement based on Ohm's law and cell constant.
Instructions for accessing and navigating the Conductivity parameter setup menu.
Step-by-step guide for performing one-point automatic conductivity calibration.
Instructions for performing manual conductivity calibration with custom values and adjusting the measurement.
Lists calibration errors for conductivity, including 'NOT STABLE', 'WRONG BUFFER', 'CALIBRATION TOO LONG'.
Guide on how to make conductivity measurements, including connecting the cell and interpreting stability indicators.
Details the setup menu structure for general instrument settings like Temperature Unit, Brightness, Sleep Mode.
Allows selection of which parameters to display in measurement mode, available for PC 7 Vio.
Restores the instrument to its factory default settings.
Activates or deactivates the auto-shutdown feature to save battery life.
Outlines the five-year warranty on electronic parts and conditions for coverage and exclusions.