SPECIAL FUNCTIONS
D-302016 17
Command SMS Format SMS format –
PowerMaxExpress Partition
System
1 Arm AWAY
“AWAY <code>”
or
“AW <code>”
“P# AWAY <code>”
or
“P# AW <code>”
2 Arm AWAY instant
“AWAY INST <code>”
or
“AWI <code>”
“P# AWAY INST <code>”
or
“P# AWI <code>”
3 Arm AWAY Latchkey
“LATCHKEY <code>”
or
“LK <code>”
“P# LATCHKEY <code>”
or
“P# LK <code>”
4 Arm AWAY Latchkey instant
“LATCHKEY INST <code>”
or
“LKI <code>”
“P# LATCHKEY INST <code>”
or
“P# LKI <code>”
5 Arm HOME
“HOME <code>”
or
“HM <code>”
“P# HOME <code>”
or
“P# HM <code>”
6 Arm HOME instant
“HOME INST <code>”
or
“HMI <code>”
“P# HOME INST <code>”
or
“P# HMI <code>”
7 Disarm
“DISARM <code>”
or
“DA <code>”
“P# DISARM <code>”
or
“P# DA <code>”
12 Define custom house identity
(see note)
“HOUSE NAME <code> <house ID>”
or
“HN <code> <house ID>”
“P# HOUSE NAME <code> <house ID>”
or
“P# HN <code> <house ID>”
13 Query system status “STATUS <code>”
or
“ST <code>”
“P# STATUS <code>”
Or
“P# ST <code>”
Note: House ID includes up to 16 characters, for example JOHN'S HOUSE.
Reporting by SMS
The PowerMaxExpress system can send SMS
messages to a maximum of 4 pre-selected telephone
numbers.
Example of the reported SMS messages:
JOHN’S HOME
**AWAY**
JOHN’S HOME
**DISARM**
JOHN’S HOUSE
POWERMAX: LOW BATTERY
GARAGE: LOW BATTERY
JOHN’S HOUSE
STATUS MESSAGE 01
(Event list is displayed)
Note: Status messages can be sent only to a calling
telephone whose identity number is not blocked by
the user!
Note: The PowerMaxExpress may react with a delay
to received SMS messages if a GPRS session is in
progress at the same time.
Conducting a Walk-Test
The walk-test is an indispensable operation by which
you verify that all detectors function properly, without
disturbing the neighbors with loud sirens. The test
must be performed at least once a week, and
should include all detectors in all zones.
Before performing walk-test, all the detectors must
be in normal state. Normal state is achieved when no
motion is made for at least 2 minutes.
Note: During the test period, 24-hour zones will not
cause an alarm if violated, but a fire zone will
function normally.
A typical test will take place as follows:
A. Select the desired partition (as described in
Chapter 2: Partition Selection Process). For
example, for Partition 3 the display will read
P3 RDY HH:MM P
B. Click
.
The display will read:
WALK TEST