29
The auto fan:
8.4.2.4 Evaporator low temperature T2 protection.
When the evaporator coil temp.T2 keeps lower than TE5 for 5 minutes, the compressor and outdoor
fan will shut off.
When T2 is higher than TE6, the compressor and outdoor fan will restart up.
While TE5=4°C
TE6=10°C
for , ACP-09CH25AEF, ACP-09CH25AEG, ACP-12CH35AEF,
8.4.3 Heating Mode
8.4.3.1 Compressor running rules:
Everytime the compressors start up, they will keep running for + t minutes(protections are active) and
then follow the below rules. (While+ t=7.)
When indoor room temp.T1 is higher than Tj, the compressor and outdoor fan will shut o
ff. When T1 is
l
ower than Tk, the compressor and outdoor fan will start up.
ACP-12CH35AEG models.
While TE5=3°C
TE6=14°C
for , ACP-18CH50AEF, ACP-18CH50AEG models.
Tj=Ts+3 Tk=Ts+2.