28
8.4 Operation Modes and Functions
8.4.1 Fan mode.
(1) Outdoor fan and compressor stop.
(2) Temperature setting function is disabled, and no setting temperature is displayed.
(3) Indoor fan can be set to high/med/low/auto.
(4) The louver operates same as in cooling mode.
(5) Auto fan:
8.4.2 Cooling Mode
8.4.2.1 Compressor running rules:
Once the compressor starts up, it will follow the below rules:
When indoor room temp.T1 is lower than Tn, the compressor and outdoor fan will shut off. When T1 is
higher than Tm, the compressor and outdoor fan will start up.
Tm=Ts+1, Tn=Ts.
8.4.2.2 Outdoor fan running rules:
The On-off outdoor units have single fan speed. The outdoor fan will run following the compressor
except when AC is in evaporator high temp.protection in heating mode ,condenser high
temp.protection in cooling mode, defrosting mode and the current protection.
8.4.2.3 Indoor fan running rules
In cooling mode, indoor fan runs all the time and the speed can be selected as high, medium, low and
auto.
PDF 件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vivax ACP-09CH25AEF and is the answer not in the manual?

Vivax ACP-09CH25AEF Specifications

General IconGeneral
BrandVivax
ModelACP-09CH25AEF
CategoryAir Conditioner
LanguageEnglish

Related product manuals