30
8. Troubleshooting
8.1 Indoor unit error display
For 9k, 11k, 18k
Display
Operation lamp
flash
times
Timer lamp
Failure
E1 1 X
EEPROM error
E2 2 X
Zero crossing
signal detection error
E3
3 X
Indoor fan speed has been out of control
E5 5 X
Indoor
room temperature sensor T1 open
circuit
or short circuit
E6 6 X
E
vaporator coil temperature sensor T2 open
circuit
or short circuit
EC 2 O
Refrigerant
leak detection error
For 24k
Display
Operation lamp flash times
Timer lamp
Failure
E1 1 X
EEPROM error
E2 2 X
Zero crossing
signal detection error
E3
3 X
Indoor fan speed has been out of control
.
E4
4 X
D
efault
E5 5 X
Indoor
room temperature sensor T1 open
circuit
or short circuit
E6 6 X
E
vaporator coil temperature sensor T2 open
circuit
or short circuit
EC 2 O
Refrigerant
leak detection error
E9
9 X
Indoor unit
and outdoor unit
communication error
O˄light˅ X˄off˅ ƿ˄flash˅

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vivax ACP-09CH25AERO and is the answer not in the manual?