The Specification of Power
36 Indoor Units
9. The Specification of Power
Model 12000 Btu/h
18000-24000Bt
u/h
30000 Btu/h 36000 Btu/h 36000 Btu/h
INDOOR
UNIT
POWER
Phase 1-phase 1-phase 1-phase 1-phase
Frequency and
Voltage
220-240V,
50Hz
220-240V,
50Hz
220-240V,
50Hz
220-240V,
50Hz
POWER
WIRING (mm
2
)
3×1.0 3×1.0 3×1.0 3×1.0
CIRCUIT
BREAKER/
Fuse (A)
15/10 15/10 15/10 15/10
OUTDOOR
UNIT
POWER
Phase 1-phase 1-phase 1-phase 1-phase 3-phase
Frequency and
Voltage
220-240V,
50Hz
220-240V,
50Hz
220-240V,
50Hz
220-240V,
50Hz
380-420V,
50Hz
POWER
WIRING (mm
2
)
3×2.5 3×2.5 3×2.5 3×4.0 5×2.5
CIRCUIT
BREAKER/
Fuse (A)
20/16 30/20 40/30 40/30 30/20
Indoor/Outdoor Connecting
Wiring(Weak Electric Signal)
(mm
2
)
2×0.2 2×0.2 2×0.2 2×0.2
Indoor/Outdoor Connecting
Wiring(Strong Electric Signal)
(mm
2
)
4×1.0
Model(Btu/h) 48000 60000 48000-60000
INDOOR UNIT
POWER
Phase 1-phase 1-phase 1-phase
Frequency and
Voltage
220-240V, 50Hz 220-240V, 50Hz 220-240V, 50Hz
Power Wiring
(mm
2
)
3×1.0 3×1.0 3×1.0
Circuit Breaker/Fuse
(A)
15/10 15/10 15/10
OUTDOOR UNIT
POWER
Phase 1-phase 1-phase 3-phase
Frequency and
Voltage
220-240V, 50Hz 220-240V, 50Hz 380-415V, 50Hz
Power Wiring
(mm
2
)
3×4.0 3×4.0 5×2.5
Circuit Breaker/Fuse
(A)
40/35 50/40 30/25
Indoor/Outdoor Connecting Wiring
(Weak Electric Signal) (mm
2
)
2×0.2
2×0.2 2×0.2
Indoor/Outdoor Connecting Wiring
(Strong Electric Signal) (mm
2
)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vivax ACP-12CC35AECI and is the answer not in the manual?

Vivax ACP-12CC35AECI Specifications

General IconGeneral
BrandVivax
ModelACP-12CC35AECI
CategoryAir Conditioner
LanguageEnglish

Related product manuals