224 - User's Manual
rotationaffect -
<product dependent>
0/7 When rotation is enabled, some features may
become malfunction or be forced to a given
value. The affected functions are list here.
The format is "Affect API
name":"Policy":"Description"
"Policy" can be categorized into following
groups:
- (disabled) : UI turns grey and users can't select
it.
- (unchanged) : UI keeps the status as before
and user can't change it.
- (hidden) : UI is hidden.
- (fixed) : UI is fixed to one selection or value.
- (ranged) : UI is fixed to multiple selections or
values.
- (enabled) : UI is checked.
- (notsupport) : the affected function is not
available.
"Affect API name" can be described in hierarchy,
such as "exposurewin.mode.blc:disabled:"
which means blc exposure window is disabled.
API name can be one word as well, such as
"exposurelevel:fixed:6" which means
exposurelevel is fixed to level 6.
"Description" can be a nonnegative integer or
string or NULL.
"-" means no feature is affected.
* When "rotation"=0, this value must be "-"
* We support this parameter when the version
number (httpversion) is equal or greater than
0304b.