EasyManua.ls Logo

Vivotek FD8167-T - Page 153

Vivotek FD8167-T
323 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VIVOTEK
User's Manual - 153
URL Command Document for All Series
18
URL commands for FD8167
connections.
onlinenum_httppush integer 0 6/7 Current number of HTTP push
server connections.
eth_i0 <string> <blank> 1/7 Get network information from
mii-tool.
vi_i<0~(nvi-1)> <boolean> 0 1/7 Virtual input
0 => Inactive
1 => Active
7.3 digital input behavior define
Group: di_i<0~(ndi-1)>
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
normalstate high,
low
high 1/1 Indicates open circuit or
closed circuit (inactive
status)
7.4 digital output behavior define
Group: do_i<0~(ndo-1)>
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
Normalstate open,
grounded
open 1/1 Indicate open circuit or
closed circuit (inactive
status)
7.5 PIR detection behavior define
Group: pir
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
enable
<boolean>
0 1/1
Enable/disable PIR
detection

Table of Contents